Calculating the angular standard deviation of electron beams using Fermi-Eyges theory.
نویسندگان
چکیده
Knowledge of the angular distribution of an electron beam at the applicator face is a necessary parameter in defining a beam when the Hogstrom pencil beam method of dose calculation is used. The angular spread can be found experimentally using penumbra widths measured at various distances from the applicator face. Using knowledge of the geometry and composition of the scattering foils of the linear accelerator, the angular standard deviation was calculated theoretically using Fermi-Eyges theory. The obtained angular spread values agree with experimentally derived values to within experimental error for electron energies from 6 to 21 MeV. The Fermi-Eyges calculation is fast, and can be used as a quick check to validate experimental angular spread values.
منابع مشابه
A method to determine the in-air spatial spread of clinical electron beams.
We propose and analyze in detail a method to measure the in-air spatial spread parameter of clinical electron beams. Measurements are performed at the center of the beam and below the adjustable collimators sited in asymmetrical configuration in order to avoid distortions due to the presence of the applicator. The main advantage of our procedure lies in the fact that the dose profiles are fitte...
متن کاملEvaluation of the electron energy fluence and angular distributions from a clinical accelerator. A BEAMnrc Monte Carlo study
Background: Understanding of the incident electron energy and angular distributions from clinical electron accelerators (linacs) is important for dosimetry and treatment planning. The most important goals of this study were to evaluate the energy fluence and angular distributions of electron beams from a Neptun 10PC linac using the Monte Carlo (MC) code. Materials and Methods: The lina...
متن کاملOn the accuracy of the Fokker-Planck and Fermi pencil beam equations for charged particle transport.
Electron beam dose calculations are often based on pencil beam formulas such as the Fermi-Eyges formula. The Fermi-Eyges formula gives an exact solution of the Fermi equation. The Fermi equation can be derived from a more fundamental mathematical model, the linear Boltzmann equation, in two steps. First, the linear Boltzmann equation is approximated by the Fokker-Planck equation. Second, the Fo...
متن کاملReal‐time simulator for designing electron dual scattering foil systems
PURPOSE To create a user friendly, accurate, real time computer simulator to facilitate the design of dual foil scattering systems for electron beams on radiotherapy accelerators. The simulator should allow for a relatively quick, initial design that can be refined and verified with subsequent Monte Carlo (MC) calculations and measurements. METHODS The simulator consists of an analytical algo...
متن کاملPlasma diagnostics by means of the scattering of electrons and proton beams
Scattering of energetic electron and proton beams by cold matter is significantly different from the scattering of these particles by plasma, which may be either highly ionized or dense strongly coupled plasma. This is due to the difference in the shielding of the target nuclei between the two cases. Quantitatively, we treat the problem by means of the Bethe Moliere multiple scattering theory a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 41 8 شماره
صفحات -
تاریخ انتشار 1996