Numerical Modeling of Two-layered Micropolar Fluid through an Normal and Stenosed Artery

نویسنده

  • S. Singh
چکیده

In the present work a two fluid model for blood flow through abnormally constricted human artery (stenosed artery) has been developed. The model consists of a core region of suspension of all erythrocytes assumed to be micro-polar fluid so as to include the micro-structural effects in addition to the peripheral-layer viscosity effects, and a peripheral plasma layer free from cells of any kind of Newtonian fluid. This model is used to predict the effects on physiological characteristics of blood flow in normal and stenosed condition. The significance of the present model over the existing models has been pointed out by comparing the results with other theories both analytically and numerically.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Modeling of Two-Layered Micropolar Fluid Through an Normal and Stenosed Artery

In the present work a two fluid model for blood flow through abnormally constrictedhuman artery (stenosed artery) has been developed. The model consists of a core region of suspensionof all erythrocytes assumed to be micro-polar fluid so as to include the micro-structural effects inaddition to the peripheral-layer viscosity effects, and a peripheral plasma layer free from cells of anykind of Ne...

متن کامل

Mathematical Modeling of Micropolar Blood Flow in a Stenosed Artery Under the Body Acceleration and Magnetic Field

Blood flow is modeled as non-Newtonian micropolar fluid. The non-linear governing equations of continuum and momentum in the cylindrical coordinate are being discretized using a finite difference approach and have been solved iteratively ,through Crank-Nicolson method. The blood velocity distribution, volumetric flow rate and Resistance to blood flow at the stenosis throat are computed for vari...

متن کامل

Oscillatory MHD Flow of Blood through an Artery with Mild Stenosis (RESEARCH NOTE)

The purpose of this work is to study the effect of oscillatory MHD blood flow in stenosed artery. The analytical and numerical results are obtained for oscillatory MHD blood flow, which is assumed to be a Newtonian fluid. It was also assumed that the surface roughness is of cosine shaped and the maximum height of roughness is negligible, compared with the radius of un-constricted tube. The flui...

متن کامل

Mathematical modelling of Sisko fluid flow through a stenosed ‎artery

In the present study, the nonlinear model of non-Newtonian blood flow in cosine-shape stenosed elastic artery is numerically examined. The model is carried out for axisymmetric, two-dimensional and fully developed blood flow. The vessel wall is assumed to be have time-dependent radius that is important factor for study of blood flow. The cosine-shape stenosis convert to rigid artery by using a ...

متن کامل

Numerical Investigation of Angulation Effects in Stenosed Renal Arteries

Background: Numerical study of angulation effects of renal arteries on blood flow has been of great interest for many researchers.Objective: This paper aims at numerically determining the angulation effects of stenosed renal arteries on blood flow velocity and renal mass flow.Method: An anatomically realistic model of abdominal aorta and renal arteries is reconstructed from CT-scan images and u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011