Commissioning Results and Improvements of the Machine Protection Sytem for Petra Iii
نویسنده
چکیده
PETRA III is a high brilliant synchrotron light-source operating at 6GeV. The commissioning of the machine had started in April 2009 [1]. In the first months of operation the Machine Protection System (MPS) ran on basic MPS requirements to protect absorbers and vacuum chambers in the damping wiggler section and the undulator section against synchrotron light. Therefore several alarms distributed along the machine are identified and within 100μs a dump command is created. The beam is dumped within 400μs by switching off the RF system [2]. Prior to the first user runs different improvements increasing the reliability and availability were planned and partly implemented in the MPS. This paper presents commissioning results of the system and gives an overview of these new implementations as well as a more detailed discussion of some alarm conditions and the dump procedure. Additionally some key aspects of the Temperature Interlock as one major alarm deliverer are described.
منابع مشابه
Evaluation of a systemic change of Superficial X-ray tube characteristics
Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...
متن کاملCommissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran
Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...
متن کاملCommissioning and early experience with a new generation low-energy linear accelerator in zahedan
Introduction: Since commissioning beam data are treated as a reference and ultimately used by treatment planning systems, it is vitally important that the collected data are of the highest quality to avoid dosimetric and patient treatment errors that may subsequently lead to a poor radiation outcome. Beam data commissioning should be performed with appropriate knowledge and pr...
متن کاملOnline Voltage Stability Monitoring and Prediction by Using Support Vector Machine Considering Overcurrent Protection for Transmission Lines
In this paper, a novel method is proposed to monitor the power system voltage stability using Support Vector Machine (SVM) by implementing real-time data received from the Wide Area Measurement System (WAMS). In this study, the effects of the protection schemes on the voltage magnitude of the buses are considered while they have not been investigated in previous researches. Considering overcurr...
متن کاملP-187: Challenges of Commissioning Mothers in Iran for Selection of Surrogate Mothers
s:1640:"Background: Surrogacy is one of the most controversial procedures in infertility treatment. Despite increasing of using this technology in Iran, there are few practical data about surrogacy. There isn't any study assessing experiences of commissioning mothers about surrogate mother selection. The purpose of this study was exploring of commissioning mothers' experiences in sele...
متن کامل