Comfort and pressure profiles of two auto-adjustable positive airway pressure devices: a technical report.

نویسندگان

  • Katrien B Hertegonne
  • Pascal M Proot
  • Romain A Pauwels
  • Dirk A Pevernagie
چکیده

STUDY OBJECTIVES The purpose of this study was to compare comfort parameters and pressure profiles of the AutoSet (Resmed) and the SOMNOsmart (Weinmann), two auto-adjustable positive airway pressure (APAP) devices. SETTING The sleep disorders center of a university hospital. DESIGN A single-blind randomized trial protocol was applied. A split night procedure allowed each patient to be treated in a crossover fashion with both APAP devices during one overnight study. PATIENTS AND METHODS Fifty consecutive obstructive sleep apnea (OSA) patients were recruited. Each patient filled out an evaluation form for both devices after the study night. Visual analogue scales were used to score four comfort measures. Three CPAP outcomes generated by the devices (P50, P95 and Pmax) were assessed, compared with each other and correlated with the individually predicted CPAP (Ppred). RESULTS Forty-five males and 5 females, mean age 53.0 years, body mass index 31.0, were included. The mean apnea-hypopnea index was 58.7, the mean arousal index was 54.3. Mean CPAP-compliance before the titration study was 4.9 h per night. Comparison of the two devices regarding the effect on the subjective sleep quality parameters showed no differences. The AutoSet pressure outcomes correlated significantly better with Ppred in comparison with the SOMNOsmart. The P50 and P95 but not the Pmax values were significantly lower in the SOMNOsmart as compared with the AutoSet (P50: 5.1+/-1.3 vs 7.1 +/- 1.9 mbar, P<0.0001; P95: 7.8+/-3.0 vs 9.6+/-1.9 mbar, P<0.0005; Pmax: 10.0+/-3.4 vs 10.8+/-1.8 mbar, NS). CONCLUSION While the subjective tolerance of the two APAP machines was comparable, these devices were characterized by different pressure profiles. The pressure parameters of the AutoSet correlated better with Ppred than those of the SOMNOsmart.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea.

Auto-adjustable continuous positive airway pressure (APAP) devices are an emerging treatment alternative to fixed-pressure continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea syndrome. They have been engineered to automatically adjust the pressure to the optimal level on a continuous basis. However, not all APAP technologies use the same algorithm. Three different AP...

متن کامل

Continuous positive airway pressure therapy: new generations.

Continuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea syndrome (OSAS). However, CPAP is not tolerated by all patients with OSAS and alternative modes of pressure delivery have been developed to overcome pressure intolerance, thereby improving patient comfort and adherence. Auto-adjustable positive airway pressure (APAP) devices may be utilised for th...

متن کامل

Snoring detection during auto-nasal continuous positive airway pressure.

A bench study using an artificial lung model was performed to evaluate the snoring detection sensitivity of six (commercially available) auto-nasal continuous positive airway pressure (NCPAP) devices. Snoring was simulated by a loudspeaker connected to the lung model and abruptly activated during 1 s of each inspiratory period to induce pressure oscillation. The oscillation frequencies chosen w...

متن کامل

Two months follow up of auto-CPAP treatment in patients with obstructive sleep apnoea.

BACKGROUND Continuous positive airway pressure (CPAP) with fixed mask pressure is the current standard treatment for obstructive sleep apnoea (OSA). Auto-CPAP devices apply at any time the minimally required pressure to normalise breathing and may improve patient comfort and compliance. We present an open descriptive study of auto-CPAP treatment at home in patients previously managed with conve...

متن کامل

Heated Humidified High-Flow Nasal Cannula Versus Nasal Continuous Positive Airway Pressure for the Facilitation of Extubation in Preterm Neonates with Respiratory Distress

Background: Heated humidified high-flow nasal cannula (HHHFNC) is gaining popularity as an alternative to nasal continuous positive airway pressure (nCPAP) therapy in the management of preterm neonates with respiratory distress due to ease of administration and patient comfort. However, limited evidence is available addressing its risks and benefits. To study the efficacy and safety of HHHFNC i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory medicine

دوره 97 8  شماره 

صفحات  -

تاریخ انتشار 2003