Matching X-ray source, optics and detectors to protein crystallography requirements.

نویسنده

  • C Nave
چکیده

A review of the requirements for collecting X-ray diffraction data from protein crystals is given, with an emphasis on the properties of the crystal and its diffraction pattern. The size, unit-cell dimensions and perfection of the crystals can all be related to the required size and divergence of the incident X-ray beam, together with the size and spatial resolution of the detector. The X-ray beam causes primary radiation damage, even in frozen crystals. If the incident beam is very intense, temperature rises and gradients could occur in the crystal. The extent to which these problems can be overcome is also discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extending The Methodology Of X-ray Crystallography To Allow X-ray Microscopy Without X-ray Optics

We demonstrate that the soft X-ray diffraction pattern from a micron-size noncrystalline specimen can be recorded and inverted to form a high-resolution image. The phase problem is overcome by oversampling the diffraction pattern. The image is obtained using an iterative algorithm. The technique provides a method for X-ray microscopy requiring no highresolution X-ray optical elements or detecto...

متن کامل

Suite of three protein crystallography beamlines with single superconducting bend magnet as the source.

At the Advanced Light Source, three protein crystallography beamlines have been built that use as a source one of the three 6 T single-pole superconducting bending magnets (superbends) that were recently installed in the ring. The use of such single-pole superconducting bend magnets enables the development of a hard X-ray program on a relatively low-energy 1.9 GeV ring without taking up inserti...

متن کامل

The X-ray Transform and its Application in Nano Crystallography

In this article a review on the definition of the X- ray transform and some ofits applications in Nano crystallography is presented. We shall show that the X- raytransform is a special case of the Radon transform on homogeneous spaces when thetopological group E(n)- the Euclidean group - acts on ℝ2 transitively. First someproperties of the Radon transform are investigated then the relationship ...

متن کامل

Experiences with CCD detectors on a home X-ray source.

Charged-coupled device (CCD) detectors have been widely accepted as detectors for collecting X-ray diffraction images. The CCD detector offers a sensitive detection system well suited for diffraction analysis and, compared with other detectors on the market, a relatively rapid system for read-out of the collected image. The two predominant markets for the CCD detector have been those in which r...

متن کامل

Accurate determination of segmented X-ray detector geometry.

Recent advances in X-ray detector technology have resulted in the introduction of segmented detectors composed of many small detector modules tiled together to cover a large detection area. Due to mechanical tolerances and the desire to be able to change the module layout to suit the needs of different experiments, the pixels on each module might not align perfectly on a regular grid. Several d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta crystallographica. Section D, Biological crystallography

دوره 55 Pt 10  شماره 

صفحات  -

تاریخ انتشار 1999