OBJECTIVE To apply a fully automated method to quantify the 3D structure of the bony nasolacrimal canal (NLC) from CT scans whereby the size and main morphometric characteristics of the canal can be determined. DESIGN Cross-sectional study. SUBJECTS 36 eyes of 18 healthy individuals. METHODS Using software designed to detect the boundaries of the NLC on CT images, 36 NLC reconstructions were prepared. These reconstructions were then used to calculate NLC volume. The NLC axis in each case was determined according to a polygonal model and to 2nd, 3rd and 4th degree polynomials. From these models, NLC sectional areas and length were determined. For each variable, descriptive statistics and normality tests (Kolmogorov-Smirnov and Shapiro-Wilk) were established. MAIN OUTCOME MEASURES Time for segmentation, NLC volume, axis, sectional areas and length. RESULTS Mean processing time was around 30 seconds for segmenting each canal. All the variables generated were normally distributed. Measurements obtained using the four models polygonal, 2nd, 3rd and 4th degree polynomial, respectively, were: mean canal length 14.74, 14.3, 14.80, and 15.03 mm; mean sectional area 15.15, 11.77, 11.43, and 11.56 mm2; minimum sectional area 8.69, 7.62, 7.40, and 7.19 mm2; and mean depth of minimum sectional area (craniocaudal) 7.85, 7.71, 8.19, and 8.08 mm. CONCLUSION The method proposed automatically reconstructs the NLC on CT scans. Using these reconstructions, morphometric measurements can be calculated from NLC axis estimates based on polygonal and 2nd, 3rd and 4th polynomial models.
منابع مشابه
Three-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography
The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...
متن کامل3-D computed tomography reconstruction: another tool to teach anatomy in the veterinary colleges
This letter underpins the use of three-dimensional computed tomography (3D-CT) reconstruction as an aid to teach veterinary anatomy. Cases were presented to students in order to observe normal and clinically abnormal patients. The images provided excellent details of relevant structures and could serve as a tool for teaching anatomy. Many sources describe different options to enhance anatomical...
متن کاملUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملEvaluation of mandibular premolars root canal morphology by cone beam computed tomography
Introduction: To achieve a successful endodontic treatment, the clinician has to identify the different canal configurations.mandibular premolars have the wide variety of root canal morphology and they are known as the most difficult teeth to treat in endodontics.CBCT provides a non-invasive 3D confirmatory diagnosis as a complement to conventional radiography.The aim of this study was to...
متن کاملA Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures
Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...
متن کامل