On Predicting Scan Profiles: the Nature of the 'Aberration Function' BY RICCARDO DESTRO
نویسنده
چکیده
In an earlier t reatment [Destro & Marsh (1987). Acta Cryst. A43, 711-718], an at tempt was made to predict the shapes of high-angle 0-20 scan profiles by convoluting a low-angle profile with the presumedly known spectral distr ibution function for the incident (crys ta l -monochromat ized Mo K a ) radiation but it was found necessary to introduce a third component, an 'aberrat ion funct ion ' , that varied with the Bragg angle 0. It is shown here that the pr imary purpose of the aberrat ion funct ion is to correct for defects in the spectral-distr ibution function. In particular, the effective intensity ratio between the Ka2 and Kal spectral lines can apparent ly deviate greatly (by more than 10%) from the theoretical value of 0.499, depend ing upon the a l ignment of the monochromator crystal, and an appreciable amount of white radiat ion may also be present. By a suitable modif icat ion of the spectral-distr ibution function, high-angle scan profiles can be predicted from accurate measurements of a low-angle profile; as a result, scan-truncat ion losses can, for the most part, be removed. However, model ing the spectral distribution funct ion appropria te to a part icular exper iment remains a difficult empir ical procedure.
منابع مشابه
Can previous thyroid scan induce cytogenetic radioadaptive response in patients treated by radioiodine for hyperthyroidism?
Background: Induction of radioadaptive responses in cells pretreated with a low dose radiation before exposure to a high dose is well documented by many investigators. The aim of this study is to determine the frequency of chromosomal aberration in peripheral blood lymphocytes of patients treated by radioiodine (131I) for hyperthyroidism, with or without previous thyroid scan with 99mTc. Materi...
متن کاملAssessment of the individual renal function in chronic unilateral renal obstruction using functional CT as compared to 99mTc-DTPA renal scan
Introduction: The selection of optimal treatment of obstructive nephrouropathy requires information about the functional status of each kidney. Nuclear renal scanning objectively measure differential renal function, multiple studies have demonstrated the role of assessment of renal perfusion and GFR with triphasic CT. The aim of this study is to assess the role of CT based on renal parenchyma...
متن کاملاصلاح توام نقص ابیراهی لنز دوربین و خطای خروج از مرکز تصویر با بهرهگیری از مدل اصلاح شده زرنیک
Reduction of the quality of the image formed by an optical system is a function of different parameters such as lens aberrations, CCD digitization errors, and the errors of system assembling. Assembling errors usually consist of two types: 1) the prism error, which is the error of non-orthogonality of the optical axis and the image plane 2) the de-centering error, which is error of not passing ...
متن کاملAn Efficient Economic-Statistical Design of Simple Linear Profiles Using a Hybrid Approach of Data Envelopment Analysis, Taguchi Loss Function, and MOPSO
Statistically constrained economic design for profiles usually refers to the selection of some parameters such as the sample size, sampling interval, smoothing constant, and control limit for minimizing the total implementation cost while the designed profiles demonstrate a proper statistical performance. In this paper, the Lorenzen-Vance function is first used to model the implementation...
متن کاملInvestigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan
Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...
متن کامل