Ocular Response Analyzer

نویسندگان

  • Sushmita Kaushik
  • Surinder Singh Pandav
چکیده

Until recently, corneal biomechanical properties could not be measured in vivo. The ocular response analyzer is a new, noninvasive device that analyses corneal biomechanical properties simply and rapidly. The ORA allows cornea compensated IOP measurements and can estimate corneal hysteresis (CH) and corneal resistance factor (CRF). It is designed to improve the accuracy of IOP measurement by using corneal biomechanical data to calculate a biomechanically adjusted estimate of intraocular pressure. This review critically evaluates the technology and its implications in current day glaucoma management.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه دقت سنجش فشار داخل چشمی پس از پیوند نافذ قرنیه توسط تحلیل‌کننده پاسخ چشمی (Ocular Response Analyzer) با تونومتر تماسی گلدمن

هـدف: مقایسه فشار داخل چشمی اندازه‌گیری‌شده توسط دستگاه تحلیل‌کننده پاسخ چشمی (Ocular Response Analyzer, ORA) با تونومتر گلدمن (Goldmann Applanation Tonometer; GAT) و ارزیابی تاثیر ویژگی‌های آناتومیکی و بیومکانیکی پیوند بر روی مقادیر فشار داخل چشمی در چشم‌های مبتلا به قوز قرنیه که ‌تحت عمل جراحی پیوند نافذ قرنیه (Penetrating keratoplasty; PKP) قرار گرفته‌اند. روش پژوهش: این مطالعه مقطعی، ب...

متن کامل

Measurement and analysis of the air pressure curve on the rigid lenses by use of ocular response analyzer.

PURPOSE Pressure curves obtained from Ocular Response Analyzer (ORA) differ for the same patient in form and height. In some cases measurements on the subject show significant differences between recorded pressure curves. The purpose of the paper is to examine if the differences result from the corneal properties or from the device operation. METHODS Examination of air pressure curves was car...

متن کامل

Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients

INTRODUCTION Apical protrusion in the central 4-mm ring in the Scheimflug imaging (Pentacam), both for the anterior and posterior floats as well as Corneal Hysteresis and Corneal Resistance Factor by Ocular Response Analyzer (ORA), generally are considered important predictors for post-Lasik ectasia. The aim of this work was to find out if there is a statistically significant correlation betwee...

متن کامل

A clinical description of Ocular Response Analyzer measurements.

PURPOSE To examine the interrelationships among the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY), Goldmann applanation tonometer (GAT), and corneal geometry measurements in a young, healthy sample. METHODS Central corneal radius, ORA, GAT, and central corneal thickness (CCT) measurements were taken in 99 subjects (age, 21 ± 2 years) who were free of ocular and ...

متن کامل

Biomechanical parameters of the cornea measured with the Ocular Response Analyzer in normal eyes

BACKGROUND To evaluate the relationships between Reichert Ocular Response Analyzer (ORA) parameters corneal hysteresis (CH) and corneal response factor (CRF) and ocular dimensions, age and intraocular pressure. METHODS Two hundred and twelve eyes of 212 participants with no ocular pathology had CH and CRF measured with the ORA. Intraocular pressure (IOP) was measured with the Dynamic Contour ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012