A new micro-respirometer with automatic setting and recording apparatus.
نویسنده
چکیده
The instrument was designed to measure the O2 uptake of living material which consumes between o-oi and 5-0 yl. O2/ hr. Its accuracy is +o-ooi /u.1., and it has the following advantages over other micro-respirometers of similar sensitivity. (a) It is robust, easy to handle and is suitable for routine use. (b) The respirometer constant is independent of the gas volume of the reaction vessel. (c) Its sensitivity is independent of the volume of the reaction vessel, and it can therefore be used with relatively large amounts of living material. (d) Experiments can be carried out over a wide range of temperatures without appreciably altering the accuracy. (e) It can be coupled to apparatus (described at the end of this paper), which automatically measures and records the rate of O2 uptake. A comprehensive review of the better known micro-respirometers has been given by Tobias (1943), but to facilitate comparison with the present instrument a list of the characteristics of some of them are given in Table 1.
منابع مشابه
Mechanical Behavior of Concrete, Made with Micro-Nano Air Bubbles
Nano materials have been widely used in laboratory and industrial scales in order to improve various properties of concrete and concrete mixture. The mainstream practice of the researches in this field is to add metallic nano-particles into the concrete mixture. The present research focuses on adding Micro-Nano Air Bubbles (MNAB) into water before mixing it with aggregate and cement mixtures. I...
متن کاملEvaluation of the total carbonaceous biochemical oxygen demand method, using a compensated recording respirometer.
The total carbonaceous biochemical oxygen demand test is described, and experimental data demonstrating its stoichiometry, precision, and accuracy are presented. The test is more reproducible and faster than the current 5-day biochemical oxygen demand test procedure, and if a respirometer is used, the effects of toxic chemicals, pH changes, and nutrient imbalances can be routinely monitored. Th...
متن کاملA Differential Volumeter for Micro-respiration Measurements
A modified micro-respirometer employing the differential volumeter principle, and mechanical accessories for the same, are described. The apparatus enables addition of solutions to be made to the biological material during the experiment. It is of a high sensitivity, a drop movement of 1.0 mm. indicating a volume change of about 0.06 c.mm. It may be used with very small amounts of biological ma...
متن کامل[A multi-purpose voice recording and encoding device using a micro computer].
A device for recording and encoding voice stimuli was developed with the NEC-PC 9801 micro computer. Sampling times are 100 microseconds (10 kHz), and one recording time can be lasted up to 15 s. The sound stimuli are monitored on the computer display. These stimuli could be edited directly by the cursor and saved onto a floppy disk. A multi purpose program was also developed for this apparatus...
متن کاملInfluence of Pipeline Operating Pressure on Value Setting of Automatic Control Valves at Different Pressure Drop Rates
When a natural gas pipeline ruptures, the adjacent upstream and downstream automatic control valves (ACV) should close quickly to prevent leakage or explosion. The differential pressure set point (DPS) at each valve location is the main criteria for value setting in ACV actions. If the DPS is not properly adjusted, the ACV may mistakenly close or it may not take any actions at a proper ti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of experimental biology
دوره 27 3-4 شماره
صفحات -
تاریخ انتشار 1950