SPAIDE: A Real-time Research Platform for the Clarion CII/90K Cochlear Implant

نویسندگان

  • Luc Van Immerseel
  • S. Peeters
  • P. Dykmans
  • Filiep Vanpoucke
  • Paul Bracken
چکیده

SPAIDE (sound-processing algorithm integrated development environment) is a real-time platform of Advanced Bionics Corporation (Sylmar, Calif, USA) to facilitate advanced research on sound-processing and electrical-stimulation strategies with the Clarion CII and 90K implants. The platform is meant for testing in the laboratory. SPAIDE is conceptually based on a clear separation of the sound-processing and stimulation strategies, and, in specific, on the distinction between sound-processing and stimulation channels and electrode contacts. The development environment has a user-friendly interface to specify sound-processing and stimulation strategies, and includes the possibility to simulate the electrical stimulation. SPAIDE allows for real-time sound capturing from file or audio input on PC, sound processing and application of the stimulation strategy, and streaming the results to the implant. The platform is able to cover a broad range of research applications; from noise reduction and mimicking of normal hearing, over complex (simultaneous) stimulation strategies, to psychophysics. The hardware setup consists of a personal computer, an interface board, and a speech processor. The software is both expandable and to a great extent reusable in other applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the ‘Fitting to Outcomes eXpert’ (FOX<sup>®</sup>) with established cochlear implant users

Objectives: To evaluate the possible impact of ‘Fitting to Outcomes eXpert (FOX)’ on cochlear implant (CI) fitting in a clinic with extensive experience of fitting a range of CI systems, as a way to assess whether a software tool such as FOX is able to complement standard clinical procedures. Methods: Ten adult post-lingually deafened and unilateral long-term users of the Advanced Bionics CI sy...

متن کامل

Virtual channel discrimination is improved by current focusing in cochlear implant recipients.

Cochlear implant users' spectral resolution is limited by both the number of implanted electrodes and channel interactions between electrodes. Current steering (virtual channels) between two adjacent monopolar electrodes has been used to increase the number of spectral channels across the electrode array. However, monopolar stimulation is associated with large current spread and increased chann...

متن کامل

Clinical relevance of quality of life outcome in cochlear implantation in postlingually deafened adults.

OBJECTIVES To evaluate the benefits of cochlear implantation in postlingually deafened adults and estimate the clinical relevance of these benefits. STUDY DESIGN Prospective intervention study. SETTING Tertiary referral hospital. PATIENTS Forty-four postlingually deafened adults. INTERVENTIONS Cochlear implantation with a Clarion CII HiFocus 1 or HiRes 90K. MAIN OUTCOME MEASURES The H...

متن کامل

Use of a sigmoidal-shaped function for noise attenuation in cochlear implants.

A new noise reduction algorithm is proposed for cochlear implants that applies attenuation to the noisy envelopes inversely proportional to the estimated signal-to-noise ratio (SNR) in each channel. The performance of the proposed noise reduction algorithm is evaluated with nine Clarion CII cochlear implant patients using IEEE sentences embedded in multi-talker babble and speech-shaped noise at...

متن کامل

Optimizing the number of electrodes with high-rate stimulation of the clarion CII cochlear implant.

OBJECTIVE This blind crossover study evaluates the effect of the number of electrodes of the Clarion CII cochlear implant on speech perception in silence and in noise using a "high-rate" continuous interleaved sampling (CIS) strategy. MATERIAL AND METHODS Nine users of this implant with 3-11 months of experience of an 8-channel CIS strategy [833 pulses per second (pps)/channel, 75 micros/phas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • EURASIP J. Adv. Sig. Proc.

دوره 2005  شماره 

صفحات  -

تاریخ انتشار 2005