Use of the peripheral cutting balloon to treat hemodialysis-related stenoses.

نویسندگان

  • Thomas M Vesely
  • Jeffrey B Siegel
چکیده

PURPOSE To compare the effectiveness and safety of use of the peripheral cutting balloon (PCB) versus standard percutaneous transluminal angioplasty (PTA) for the treatment of hemodialysis-related stenoses. MATERIALS AND METHODS This prospective, randomized multicenter clinical trial included 340 patients with stenotic or thrombosed hemodialysis grafts who were randomized to receive treatment with the PCB or PTA for venous outflow stenosis. One hundred seventy-three patients underwent treatment with the PCB, 101 with stenotic grafts and 72 with thrombosed grafts. PTA was used to treat 167 patients, 94 patients with stenotic grafts and 73 with thrombosed grafts. The follow-up period extended for 6 months. RESULTS The procedural success rates were 80.8% and 75.4% for the PCB and PTA groups, respectively (P = .24). With use of the PCB, the primary patency rates of the target lesions were 84.3%, 65.8%, and 47.9% at 1 month, 3 months, and 6 months, respectively. With PTA, the primary patency rates of the target lesions were 77.7%, 63.4%, and 40.5% at 1 month, 3 months, and 6 months, respectively. The primary patency rates of the entire vascular access circuit were 82.6%, 61.0%, and 43.3% at 1 month, 3 months, and 6 months, respectively, with use of the PCB. For patients who were treated with PTA, the primary patency rates of the vascular access circuit were 75.9%, 61.0%, and 36.3% at 1 month, 3 months, and 6 months, respectively. When comparing the PCB and PTA, there was no difference in the 6-month primary patency rates in the target lesion (P = .373) or the entire vascular access circuit (P = .531). There were nine device-related complications in the PCB group (5.2%): five venous ruptures (2.9%), three venous dissections (1.7%), and one case of thrombosis (0.6%). There were no device-related complications in the PTA group. CONCLUSION This prospective, randomized trial comparing use of the PCB versus standard PTA for treatment of hemodialysis-related venous stenoses demonstrated that the PCB provides equivalent 6-month patency to PTA for stenotic and thrombosed grafts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using 6-mm Cutting Balloon angioplasty in patients with resistant peripheral artery stenosis: preliminary results.

OBJECTIVE The objective of this study was to assess the efficacy of 6-mm Cutting Balloon angioplasty in patients with resistant peripheral stenoses caused by neointimal hyperplasia or irradiation-induced arteriopathy in vascular territories that are not amenable for use of the smaller Cutting Balloons that are used in cardiology. CONCLUSION Peripheral Cutting Balloon angioplasty with the new ...

متن کامل

Angioplasty balloon inflation pressures during treatment of hemodialysis graft-related stenoses.

PURPOSE This two-part prospective investigation was designed to determine the balloon inflation pressures required to dilate stenoses associated with hemodialysis grafts and evaluate the burst pressures of five different angioplasty balloons. MATERIALS AND METHODS Eighty-nine patients with dysfunctional hemodialysis grafts were enrolled and underwent fistulography. The diagnostic studies reve...

متن کامل

Vascular rupture during angioplasty of hemodialysis raft-related stenoses.

PURPOSE To retrospectively determine the incidence and outcome of angioplasty-induced ruptures that occurred during treatment of hemodialysis graft-related stenoses. MATERIALS AND METHODS During a five year period 1222 patients with dysfunctional or thrombosed polytetrafluoroethylene (PTFE) hemodialysis grafts underwent angioplasty procedures at our institution. Angioplasty-induced vascular r...

متن کامل

The experience use of drug-coated & non drug-coated balloons in arteriovenous fistula at a six months period: brief report

Background: The ineffectiveness of hemodialysis fistulas causes high costs and increases mortality and morbidity rates. The efficacy of drug-coated balloon and nondrug-coated balloon in dysfunctional arteriovenous Fistula was evaluated over six month period. Methods: In this randomized clinical trial, a total of a total of 50 hemodialysis patients who referred to Imam Reza Hospital in Kermansh...

متن کامل

Renal artery rupture following cutting balloon angioplasty for fibromuscular dysplasia: a case report

INTRODUCTION Angioplasty with the use of cutting balloons has been suggested by some case reports and small series for the treatment of renal artery stenoses that are resistant to conventional balloon catheters. Based on this limited experience, the use of this technology has been suggested as safe. Herein, we report a renal artery rupture following angioplasty with a cutting balloon. The compl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular and interventional radiology : JVIR

دوره 16 12  شماره 

صفحات  -

تاریخ انتشار 2005