Total knee arthroplasty using computer-assisted navigation in patients with deformities of the femur and tibia.
نویسندگان
چکیده
Anatomic aberrations of the femur and tibia secondary to trauma, congenital defects, and prior surgery present challenges for the reconstructive knee surgeon because of an altered mechanical axis and distorted anatomic landmarks. Five patients with arthritis of the knee and extra-articular femoral and/or tibial deformity, retained hardware, or intramedullary (IM) implants underwent total knee arthroplasty using a computer navigation system. The navigation system obviated the need for an IM guide, and the normal mechanical axis of the patients was restored. Extensive dissection for hardware removal or osteotomy was not necessary in these patients. In these 5 cases, a navigation system proved to be an effective tool for restoration of limb alignment in the presence of significant extra-articular deformities and/or IM hardware. Thus, it provides an alternative approach to the traditional IM instrumentation for treating these patients in an effective manner.
منابع مشابه
Navigated total knee arthroplasty in a patient with severe diaphyseal deformities.
A 65-year-old patient presented with severe osteoarthritis of the knee, 47 years after a severe polytrauma in which he had presented diaphyseal fractures of the left femur and tibia. These fractures had been treated conservatively and had healed with major deformities. He underwent total knee arthroplasty with navigation assistance. This allowed for optimal component positioning and restoration...
متن کاملDoes computer-assisted surgical navigation total knee arthroplasty reduce venous thromboembolism compared with conventional total knee arthroplasty?
INTRODUCTION The study aims to show that total knee arthroplasty using computer-assisted surgical navigation without intramedullary rodding is safer than conventional intramedullary techniques in preventing venous thromboembolism. METHODS 30 patients were grouped into groups of 10. Groups A and B had conventional intramedullary rodding of the femur and/or tibia. Group C had no rodding of the ...
متن کاملAnalysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based Study of 449 Cases
Background: The aim of this study is to evaluate the geometry of the distal femur and the proximal tibia in the osteoarthritic knee using 3D reconstructive CT scan imaging. Methods: 449 patients with knee osteoarthritis were treated surgically in our center with patient-specific technology total knee arthroplasty. Preoperatively, all the patients underwent a CT scan according to a standard ...
متن کاملAre systemic emboli reduced in computer-assisted knee surgery?: A prospective, randomised, clinical trial.
We undertook a prospective, randomised study using a non-invasive transcranial Doppler device to evaluate cranial embolisation in computer-assisted navigated total knee arthroplasty (n = 14) and compared this with a standard conventional surgical technique using intramedullary alignment guides (n = 10). All patients were selected randomly without the knowledge of the patient, anaesthetists (bef...
متن کاملInaccurate rotational component position in image-free navigated unicompartmental knee arthroplasty
Background/Objective The success of unicompartmental knee arthroplasty (UKA) is highly dependent on the accuracy of component and leg alignment. Computer-assisted surgery is gaining popularity in total knee arthroplasty with numerous studies reporting improved accuracy and decreased variability in implant position and postoperative limb alignment compared with conventional techniques. However, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 21 2 شماره
صفحات -
تاریخ انتشار 2006