Assessment Of The Effectiveness Of Collimation Of Cs–137 Panoramic Beam On Tld Calibration Using A Constructed Lead Block Collimator And An ICRU Slab Phantom At SSDL In Ghana
نویسنده
چکیده
The objective of calibrating TLD badges and radiation survey meters demand that accurate dose gets to the TLDs and radiation survey meters. A lead block mould and an ICRU slab phantom had been designed and constructed to collimate the panoramic Cs-137 source at the secondary standards dosimetry laboratory (SSDL) by experts at the National Nuclear Research Institute (NNRI) workshop of the Ghana Atomic Energy Commission according to required specifications. This is to concentrate the panoramic isotropic emission into narrow beam geometry to enhance the calibration of personnel dosimeters and radiation survey meters and further reduces scattered radiations due to backscatter and transmission through the biological shield. The designed block was tested by a series of dose measurement of 1mSv using thermoluminescent dosimeters (TLDs) placed on a standardized ICRU slab phantom to cater for backscatter conditions of the human body at specified distances of 1, 2 and 3 meters with and without the collimation. The transmission dose rates measurements through the biological shield were taken by a survey meter. The results show percentage distribution of an effective reduction of transmitted dose rate to the laboratories and offices. However, the lead door recorded very high transmitted dose rates. It was finally concluded that further collimation will be necessary to completely eliminate scatter radiations introduced by the panoramic bench and transmission through the lead door.
منابع مشابه
Preliminary Investigations of the Contribution of Scatter Radiation During Calibration of TLD-100 Using a Cs-137 Panoramic Source
Studies were carried out to determine the contribution of secondary photons to the calibration set-up of a Secondary Standard Dosimetry Laboratory. In these studies the response of LiF:Mg TLD-100 to known exposures using Cs-137 panoramic-source were investigated. Each TLD chip showed a linear dose response to radiation, demonstrating a typical characteristic of LiF:Mg chips. Whilst TLDs showed ...
متن کاملDevelopment of a prototype stereotactic collimation assembly for Neptun 10 PC linac
Background: A set of hardware stereotactic radiosurgery is designed and constructed. The scope of this article is to describe how we have designed and developed stereotactic collimation assembly for a 9 MV Neptun 10 PC linac. Materials and methods: One collimator holder and six collimators were made, with their radiation field diameter between 12.5 mm to 25 mm at isocenter level. Beam data, suc...
متن کاملBackscattering factor for some personal dosimeters and impact on Hp\(10\)
In the present paper, we estimated backscattering factors for the TLD and active personal dosimeters using 662 keV gamma-ray photons on a PMMA surface, which are, for the TLD, 1.12; Dosicard, 1.116; DRD, 0.99; and Saphydose, 1.073, and on a water slab phantom surface; for the TLD, 1.115; Dosicard, 1.112; DRD, 1; and Saphydose, 1.059. The backscattering factor contribution for the Saphydose is n...
متن کاملDesign and manufacturing a CTDI pediatric phantom for CT dosimetry using TLD, ion chambers, and gel dosimetry
Introduction: Nowadays, the demand for CT-scan is increased, and this issue has become a critical subject in radiation protection, because of the risk of cancer especially for children. The quality assurance of CT images is a necessary factor that can effect on children dose. The CT dose index is an important dosimetry index in CT-Scan dosimetry. The purpose of this study is t...
متن کاملDifferential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms
Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...
متن کامل