Geometry assessment of coronary artery anastomoses with construction errors by epicardial ultrasound.

نویسندگان

  • Thomas C Dessing
  • Ricardo P J Budde
  • Rudy Meijer
  • Patricia F A Bakker
  • Cornelius Borst
  • Paul F Gründeman
چکیده

OBJECTIVE There is concern about the quality of the distal anastomosis in off-pump coronary artery bypass grafting. We investigated the impact of specific construction errors on anastomotic geometry using epicardial ultrasound. METHODS Twelve ex vivo pressure perfused porcine and five isolated post-mortem human hearts were used to construct 35 internal mammary artery to coronary artery anastomoses, either without (n = 7) or with a standardized construction error (oversutured toe, oversutured heel, cross-over or purse string; each error, n = 7). The anastomotic geometry was visualized and measured by a 13 MHz ultrasound mini-transducer. Impression cast material was used to validate anastomotic geometry. RESULTS All 28 errors were visualized properly. Two unintended construction abnormalities were observed. In the porcine heart, the ratio of anastomotic orifice area and outflow corner area was 1.3+/-0.2 (mean+/-standard deviation) in the control group and reduced in the error groups: oversutured toe, 0.6+/-0.2 (P = 0.001 oversutured heel, 0.9+/-0.2 (P = 0.037); cross-over, 0.4+/-0.2 (P < 0.001); purse string, 0.3+/-0.2 (P < 0.001). None of the errors reduced the area of the inflow or outflow corner itself compared to the recipient coronary artery. In the human heart, all construction errors as well as wall plaque were visualized properly. In all anastomoses, ultrasound geometry corresponded to cast geometry. CONCLUSIONS Ex vivo, epicardial 13 MHz ultrasound enabled accurate visualization and assessment of four different construction errors in the coronary anastomosis. All errors reduced the area of the anastomotic orifice, but not the inflow or outflow corner.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robot-assisted 13 MHz epicardial ultrasound for endoscopic quality assessment of coronary anastomoses.

In totally endoscopic coronary artery bypass surgery, intra-operative assessment of anastomotic quality is needed. We evaluated the endoscopic application of epicardial ultrasound to visualize the coronary anastomosis and detect a construction error. In 8 pigs (71-78kg), 16 internal mammary artery to left anterior descending coronary artery anastomoses were constructed conventionally, either co...

متن کامل

Intraoperative color Doppler ultrasound assessment of LIMA-to-LAD anastomoses in off-pump coronary artery bypass grafting.

BACKGROUND Although techniques for off-pump coronary artery bypass grafting (CABG) are continually being refined, angiographic follow-up studies have indicated a higher rate of anastomoses-related stenoses than expected after traditional on-pump CABG. This study was performed to evaluate the use of intraoperative epicardial color Doppler ultrasound to quality-assess left internal mammary artery...

متن کامل

Intraoperative evaluation of coronary artery bypass graft anastomoses with high-frequency epicardial echocardiography: experimental validation and initial patient studies.

There is currently no accepted approach for intraoperative evaluation of the technical adequacy of coronary artery bypass graft anastomoses. High-frequency epicardial echocardiography performed intraoperatively could assess coronary artery bypass graft anastomoses by providing on-line short-axis (cross-sectional) and longitudinal two-dimensional images of the vessels. To validate measurements o...

متن کامل

Detection of internal thoracic artery dissection at coronary anastomosis using intraoperative 15-MHz high-frequency epicardial ultrasound.

A 66-year-old man with a history of diabetes mellitus presented with angina pectoris with 3-vessel disease, and he underwent off-pump coronary artery bypass grafting via median sternotomy. After performing bypass grafting of the left internal thoracic artery to the left anterior descending artery, the appearance of anastomosis configuration appeared to be acceptable. However, transit time flow ...

متن کامل

بررسی Longitudinal global strain (GLS) بیماران دیابتی و هایپرتنسیو مبتلا به Slow flow coronary artery و مقایسه با GLS بیماران دیابتی و هایپرتنسیو با normal epicardial coronary artery با استفاده از روش اکوکاردیوگرافی 2D

مقدمه: جریان خون آهسته کرونری (CSF) یک اختلال میکروواسکولار است که توسط تاخیر در پیشرفت روی به جلوی ماده حاجب در شاخه های انتهایی شریان کرونر و در فقدان بیماری کرونری انسدادی مشخص می شود. هدف: هدف از این مطالعه مقایسه GLS اندازه گیری شده توسط اکوکاردیوگرافی 2D در بیماران Slow flow coronary artery دیابتی و هایپرتنسیو با بیماران normal epicardial coronary artery دیابتی و هایپرتنسیو می باشد...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2004