Regularised Model Identification Improves Accuracy of Multisensor Systems for Noninvasive Continuous Glucose Monitoring in Diabetes Management

نویسندگان

  • Mattia Zanon
  • Giovanni Sparacino
  • Andrea Facchinetti
  • Mark Talary
  • Andreas Caduff
  • Claudio Cobelli
چکیده

Continuous glucose monitoring (CGM) by suitable portable sensors plays a central role in the treatment of diabetes, a disease currently affecting more than 350 million people worldwide. Noninvasive CGM (NI-CGM), in particular, is appealing for reasons related to patient comfort (no needles are used) but challenging. NI-CGM prototypes exploiting multisensor approaches have been recently proposed to deal with physiological and environmental disturbances. In these prototypes, signals measured noninvasively (e.g., skin impedance, temperature, optical skin properties, etc.) are combined through a static multivariate linear model for estimating glucose levels. In this work, by exploiting a dataset of 45 experimental sessions acquired in diabetic subjects, we show that regularisation-based techniques for the identification of the model, such as the least absolute shrinkage and selection operator (better known as LASSO), Ridge regression, and Elastic-Net regression, improve the accuracy of glucose estimates with respect to techniques, such as partial least squares regression, previously used in the literature. More specifically, the Elastic-Net model (i.e., the model identified using a combination of l 1 and l 2 norms) has the best results, according to the metrics widely accepted in the diabetes community.This model represents an important incremental step toward the development of NI-CGM devices effectively usable by patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Data processing for noninvasive continuous glucose monitoring with a multisensor device.

BACKGROUND Impedance spectroscopy has been shown to be a candidate for noninvasive continuous glucose monitoring in humans. However, in addition to glucose, other factors also have effects on impedance characteristics of the skin and underlying tissue. METHOD Impedance spectra were summarized through a principal component analysis and relevant variables were identified with Akaike's informati...

متن کامل

Identifying Significant Health Measurement of Equipment Affecting the Quality of a Continuous Product (Case Study: Unit 2, Parand Gas Turbine Power Plant)

Objective: Majorproducers consider quality as a major criterion in decision making.Quality characteristics are affected by maintenance and repair decisions. In this study, a model is developed to determine significant measurements of production equipment affecting the quality of a continuous product to identify which measurements are more critical in terms of quality. Methods: Diversity of par...

متن کامل

Glucose Biosensors: An Overview of Use in Clinical Practice

Blood glucose monitoring has been established as a valuable tool in the management of diabetes. Since maintaining normal blood glucose levels is recommended, a series of suitable glucose biosensors have been developed. During the last 50 years, glucose biosensor technology including point-of-care devices, continuous glucose monitoring systems and noninvasive glucose monitoring systems has been ...

متن کامل

Continuous noninvasive glucose monitoring technology based on "occlusion spectroscopy".

BACKGROUND A truly noninvasive glucose-sensing device could revolutionalize diabetes treatment by leading to improved compliance with recommended glucose levels, thus reducing the long-term complications and cost of diabetes. Herein, we present the technology and evaluate the efficacy of a truly noninvasive device for continuous blood glucose monitoring, the NBM (OrSense Ltd.). METHODS In vit...

متن کامل

Continuous Glucose Monitoring: A Perspective on Its Past, Present, and Future Applications for Diabetes Management

The transition from urinary glucose measurement to more sophisticated self-monitoring of blood glucose (SMBG) systems in the 1970s and 1980s dramatically changed the approach to and understanding of diabetes management (1). Innovations in the design and technology of portable blood glucose meters have become integral to the success of intensive treatment of both type 1 and type 2 diabetes, and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • J. Applied Mathematics

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013