Pulmonary emphysema: radiation dose and section thickness at multidetector CT quantification--comparison with macroscopic and microscopic morphometry.

نویسندگان

  • Afarine Madani
  • Viviane De Maertelaer
  • Jacqueline Zanen
  • Pierre Alain Gevenois
چکیده

PURPOSE To prospectively investigate the effects of radiation dose and section thickness on quantitative multidetector computed tomographic (CT) indexes of pulmonary emphysema. MATERIALS AND METHODS The institutional review board approved this protocol. Written informed consent was obtained from all patients. Seventy patients (49 men, 21 women; age range, 38-79 years) referred for surgical resection of a lung tumor underwent multidetector CT with 4 x 1-mm collimation, 120 kVp, and 20 and 120 effective mAs. At each radiation dose, 1.25-, 5.0-, and 10.0-mm-thick sections were reconstructed at 10-mm intervals. From scans of the lobe or whole lung to be resected, relative areas (RAs) of lung with attenuation coefficients lower than nine thresholds and eight percentiles of the distribution of attenuation coefficients were compared with the histopathologic extent of emphysema, which was measured microscopically--by using the corrected mean interwall distance (MIWD) and the corrected mean perimeter (MP)--and macroscopically. Correlations between the data obtained by using attenuation thresholds and percentiles and the parameters macroscopic extent of emphysema, MIWD, and MP were investigated by using Spearman coefficients. RESULTS The 1st percentile (r range, -0.394 to -0.675; P < .001) and attenuation coefficients of -980, -970, and -960 HU (r range, 0.478-0.664; P < .001) yielded the strongest correlations with macroscopic extent, MIWD, and MP, regardless of radiation dose or section thickness. The effects of radiation dose and section thickness on RAs of lung with attenuation coefficients lower than -960 HU (P = .007 and P < .001, respectively) and lower than -970 HU (P = .001 and P < .001, respectively) were significant. The effect of section thickness on the 1st percentile was significant (P < .001), whereas the effect of dose was not (P = .910). CONCLUSION At CT quantification of pulmonary emphysema, the tube current-time product can be reduced to 20 mAs, but both tube current-time product and section thickness should be kept constant in follow-up examinations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary emphysema: objective quantification at multi-detector row CT--comparison with macroscopic and microscopic morphometry.

PURPOSE To prospectively compare pulmonary function tests and helical computed tomographic (CT) indexes for quantifying pulmonary emphysema with macroscopic and microscopic morphometry. MATERIALS AND METHODS The investigation was approved by the local ethics committee, and written informed consent was obtained from patients. Multi-detector row CT of the thorax was performed with simultaneous ...

متن کامل

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

Statins for the treatment of asthma: a discovery well, dry hole or just snake oil.

and the NIH funded COPDGene Project. It is not essential to solve the dilemma of whether the term COPD expresses correctly the protean clinical presentations of the same disease or that it combines different clinical entities, but it is necessary to realise that there are needs and research opportunities in an area that is largely unknown. The words ''expira-tory airflow limitation'' expresses ...

متن کامل

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...

متن کامل

Radiation dose reduction at multidetector CT with adaptive statistical iterative reconstruction for evaluation of urolithiasis: how low can we go?

PURPOSE To evaluate the performance of computed tomographic (CT) examinations at 80 and 100 kV with tube current-time products of 75-150 mA and the effect of adaptive statistical iterative reconstruction (ASIR) on CT image quality in patients with urinary stone disease. MATERIALS AND METHODS In this HIPAA-compliant institutional review board-approved study, verbal consent for prospective low-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 243 1  شماره 

صفحات  -

تاریخ انتشار 2007