Long-Term Wear Evaluation of a Polycarbonate-Urethane Cushion Form Bearing in Artificial Hip Joints

نویسندگان

  • Jonathan J. Elsner
  • Maoz Shemesh
  • Yoav Mezape
  • Avi Shterling
  • Eran Linder-Ganz
  • Noam Eliaz
چکیده

045 ©2011 Society For Biomaterials

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear rate evaluation of a novel polycarbonate-urethane cushion form bearing for artificial hip joints.

There is growing interest in the use of compliant materials as an alternative to hard bearing materials such as polyethylene, metal and ceramics in artificial joints. Cushion form bearings based on polycarbonate-urethane (PCU) mimic the natural synovial joint more closely by promoting fluid-film lubrication. In the current study, we used a physiological simulator to evaluate the wear characteri...

متن کامل

Long-term evaluation of a compliant cushion form acetabular bearing for hip joint replacement: a 20 million cycles wear simulation.

Soft bearing materials that aim to reproduce the tribological function of the natural joint are gaining popularity as an alternative concept to conventional hard bearing materials in the hip and knee. However, it has not been proven so far that an elastic cushion bearing can be sufficiently durable as a long term (∼20 years) articulating joint prosthesis. The use of new bearing materials should...

متن کامل

Study of the Polycarbonate-Urethane/Metal Contact in Different Positions during Gait Cycle

Nowadays, a growing number of young and more active patients receive hip replacement. More strenuous activities in such patients involve higher friction and wear rates, with friction on the bearing surface being crucial to ensure arthroplasty survival in the long term. Over the last years, the polycarbonate-urethane has offered a feasible alternative to conventional bearings. A finite element m...

متن کامل

Explantation and analysis of the first retrieved human acetabular cup made of polycarbonate urethane: a case report.

This report describes the first human retrieval of a polycarbonate-urethane (PCU) acetabular cup implanted for 10.5 months that was revised for pain of unknown origin. By using a micro-CT analysis, the articulating surface was determined to have a wear rate of less than 1.4 mm3 per year. An analysis of the synovial fluid retrieved at the time of revision found an average particle size of 1 mum ...

متن کامل

Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty

The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011