A multifilamented electrode in the middle cardiac vein reduces energy requirements for defibrillation in the pig.
نویسندگان
چکیده
OBJECTIVE To compare the defibrillation efficacy of a novel lead system placed in the middle cardiac vein with a conventional non-thoracotomy lead system. METHODS In eight pigs (weighing 35-71 kg), an electrode was advanced transvenously to the right ventricular apex (RV), with the proximal electrode in the superior caval vein (SCV). Middle cardiac vein (MCV) angiography was used to delineate the anatomy before a three electrode system (length 2 x 25 mm + 1 x 50 mm) was positioned in the vein. An active housing (AH) electrode was implanted in the left pectoral region. Ventricular fibrillation was induced and biphasic shocks were delivered by an external defibrillator. The defibrillation threshold was measured and the electrode configurations randomised to: RV-->AH, RV+MCV-->AH, MCV-->AH, and RV-->SCV+AH. RESULTS For these configurations, mean (SD) defibrillation thresholds were 27.3 (9.6) J, 11.9 (2.9) J, 15.2 (4.3) J, and 21.8 (9.3) J, respectively. Both electrode configurations incorporating the MCV had defibrillation thresholds that were significantly less than those observed with the RV-->AH (p < 0.001) and RV-->SCV+AH (p < 0.05) configurations. Necropsy dissection showed that the MCV drained into the coronary sinus at a location close to its orifice (mean distance = 2.7 (2.2) mm). The MCV bifurcated into two main branches that drained the right and left ventricles, the left branch being the dominant vessel in the majority (6/7) of cases. CONCLUSIONS Placement of specialised defibrillation electrodes within the middle cardiac vein provides more effective defibrillation than a conventional tight ventricular lead.
منابع مشابه
The distribution of the cardiac veins in the New Zealand White rabbits (Oryctolagus cuniculus)
In this investigation, 25 adult New Zealand White rabbits randomly selected from both sexes and studied.Coloured latex injection and corrosion cast methods were applied on the materials. This study was carried out to disclose the distribution of the cardiac veins of the New Zealand White rabbits. The veins that drain the heart were found to be the great cardiac vein, the middle cardiac vein, th...
متن کاملImmunohistochemistric study of the intra-cardiac ganglia of the pig heart
Heart contains a variety of neurons known to influence cardiac functions. Little is known about the neurochemistry of these neurons. In this study, neurochemistry of intra cardiac neurons of the intrinsic cardiac ganglia was investigated. The technique used allows studying the morphology of the ganglionated nerve plexus found within the atria and great cardiac vessels as well as of individual n...
متن کاملImmunohistochemistric study of the intra-cardiac ganglia of the pig heart
Heart contains a variety of neurons known to influence cardiac functions. Little is known about the neurochemistry of these neurons. In this study, neurochemistry of intra cardiac neurons of the intrinsic cardiac ganglia was investigated. The technique used allows studying the morphology of the ganglionated nerve plexus found within the atria and great cardiac vessels as well as of individual n...
متن کاملBiventricular Defibrillation with Sequential Shocks Using Patient-derived Computational Models
Standard transvenous defibrillation is performed with implantable cardioverter defibrillators (ICD) using a dualcurrent pathway. The defibrillation energy is delivered from the right ventricle (RV) electrode to the superior vena cava (SVC) electrode and the ICD metallic housing. Clinical studies of biventricular defibrillation, which uses an additional electrode, placed on the left ventricular ...
متن کاملProspective, randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode.
BACKGROUND A unipolar defibrillation system using a single right ventricular (RV) electrode and the active shell or "CAN" of the implantable cardioverter-defibrillator itself situated in a left infraclavicular pocket has been shown to be as efficient in defibrillation as an epicardial lead system. The purpose of this study was to determine whether defibrillation efficacy can be improved further...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 84 4 شماره
صفحات -
تاریخ انتشار 2000