Prospects in percutaneous ablative targeting: comparison of a computer-assisted navigation system and the AcuBot Robotic System.
نویسندگان
چکیده
AIM Precise targeting is essential for adequate treatment of lesions during image-guided therapy. The aim of this study was to compare the performance of two emerging image-guided targeting technologies in a phantom model. MATERIALS AND METHODS A computer-assisted navigation system and AcuBot were tested using three operators: an interventional radiologist and two endourologists. Fiducials were placed in an anatomic gelatin phantom and targeted by both systems. The images were reconstructed and analyzed using a specialized software package (Amira; Visage Imaging, Carlsbad, CA). Accuracy was assessed by measuring proximity of the tip of the needle to the fiducial on computed-tomography-guided imaging. Accuracy and time to target were quantified and compared. RESULTS The mean distance from the desired target for AcuBot was 1.2 mm (range: 0.39-2.82). The mean distance from the desired target for the navigation system was 5.8 mm (range: 1.8-11.9). The AcuBot was significantly more accurate than the navigation system (p < 0.0001). The mean time from target acquisition to needle placement was 37 seconds (range: 15-75) for the AcuBot and 108 seconds (range: 45-315) for the navigation system (p = 0.001). CONCLUSION Emerging technologies hold promise for increased accuracy during percutaneous targeted procedures. Both the AcuBot and the computer-assisted navigation system were accurate and efficient in a phantom targeting model. AcuBot was significantly more accurate, faster, and less user dependent than the navigation system. Further studies in animal and clinical studies are warranted to further advance this promising technology.
منابع مشابه
Prospects of Robot-Assisted Mandibular Reconstruction with Fibula Flap: Comparison with a Computer-Assisted Navigation System and Freehand Technique.
Background Function and aesthetics have a significant impact on the quality of life in patients undergoing mandibular reconstructive surgery, but achieving satisfactory results remain challenging. The aim of the study is to investigate the feasibility and accuracy of robot-assisted mandibular reconstruction with fibula flap in comparison to that with a computer-assisted navigation system and th...
متن کاملAn LPV Approach to Sensor Fault Diagnosis of Robotic Arm
One of the major challenges in robotic arms is to diagnosis sensor fault. To address this challenge, this paper presents an LPV approach. Initially, the dynamics of a two-link manipulator is modelled with a polytopic linear parameter varying structure and then by using a descriptor system approach and a robust design of a suitable unknown input observer by means of pole placement method along w...
متن کاملA Hierarchical SLAM/GPS/INS Sensor Fusion with WLFP for Flying Robo-SAR's Navigation
In this paper, we present the results of a hierarchical SLAM/GPS/INS/WLFP sensor fusion to be used in navigation system devices. Due to low quality of the inertial sensors, even a short-term GPS failure can lower the integrated navigation performance significantly. In addition, in GPS denied environments, most navigation systems need a separate assisting resource, in order to increase the avail...
متن کاملPerformance Enhancement of GPS/INS Integrated Navigation System Using Wavelet Based De-noising method
Accuracy of inertial navigation system (INS) is limited by inertial sensors imperfections. Before using inertial sensors signals in the data fusion algorithm, noise removal method should be performed, in which, wavelet decomposition method is used. In this method the raw data is decomposed into high and low frequency data sets. In this study, wavelet multi-level resolution analysis (WMRA) techn...
متن کاملLaparoscopic Assisted ultrasound guided Percutaneous Nephrolithotomy (PCNL) in Ectopic Pelvic Kidney
We report a patient with pain, abdominal palpable mass and a history of previous open renal stone surgery. Imaging studies showed a right pelvic kidney with multiple calyceal stones. We describe the successful management through laparoscopic assisted percutaneous nephrolithotomy with ultrasonography (PCNL) in ectopic pelvic kidney, stressing that this method is a minimally invasive therapeutic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endourology
دوره 24 8 شماره
صفحات -
تاریخ انتشار 2010