Gradient reduction, aortic valve regurgitation and prolapse after balloon aortic valvuloplasty in 32 consecutive patients with congenital aortic stenosis.
نویسندگان
چکیده
From 1986 to 1988, balloon aortic valvuloplasty was performed in 32 patients with congenital valvular aortic stenosis. The patients ranged in age from 2 days to 28 years (mean +/- SD 8.3 +/- 5.9). One balloon was used in 17 patients and two balloons were used in 15 patients. Immediately after valvuloplasty, peak systolic pressure gradient across the aortic valve decreased significantly from 77 +/- 27 to 23 +/- 16 mm Hg (p less than 0.01), a 70% reduction in gradient. At early follow-up study (4.1 +/- 3.3 months after valvuloplasty), there was a 48 +/- 20.5% reduction in gradient compared with that before valvuloplasty, and at late follow-up evaluation (19.2 +/- 5.6 months), a reduction in gradient of 40 +/- 29% persisted. Echocardiography showed evidence of significantly increased aortic regurgitation in 10 patients (31%) and aortic valve prolapse in 7 patients (22%). There was no correlation between the balloon/anulus ratio and the subsequent development of aortic regurgitation or prolapse. In fact, no patient who showed a significant increase in aortic regurgitation had had a balloon/anulus ratio greater than 100%. It is concluded that balloon aortic valvuloplasty effectively reduces peak systolic pressure gradient across the aortic valve in patients with congenital aortic stenosis. However, subsequent aortic regurgitation and prolapse occur in a significant number of patients, even if appropriate technique and a balloon size no greater than that of the aortic anulus are used.
منابع مشابه
مقایسه نتایج درمانی بالون والوپلاستی و والوتومی جراحی در بیماران مبتلا به تنگی مادرزادی دریچه آئورت در پیگیری 6 ساله در بخش کودکان بیمارستان قلب شهید رجایی تهران
Background: Balloon valvuloplasty is a relatively new technique for relief of obstruction of aortic valve. The primary results of this procedure are similar to surgical valvotomy with fewer complications and mortality. Materials and methods: One hundred fifty-five patients with congenital aortic stenosis were enrolled in this study over a period of 6 years (1991-1997). Participants were all un...
متن کاملبررسی نتایج پیگیری یک ساله بالون والولوپلاستی تنگی مادرزادی دریچه آئورت در کودکان به مدت 10 سال در بیمارستان قلب شهید رجایی
Abstract Background: Balloon valvuloplasty uses for treatment of aortic stenosis from 20 years ago. Regarding loss of information about results of balloon valvuloplasty of hereditary aortic stenosis, this study was done to determine prognosis and complication of balloon valvuloplasty during last 10 years. Methods: This study was done on existing data of all children with hereditary aortic...
متن کاملA novel approach: trans-ascending aorta balloon aortic valvuloplasty via sternotomy for treating severe valvular aortic stenosis in a low-weight infant.
BACKGROUND Severe congenital aortic stenosis in infants is a life-threatening congenital heart anomaly that is typically treated using percutaneous balloon aortic valvuloplasty. METHODS The usual route is the femoral artery under radiographic guidance. However, this procedure may be limited by the small size of the femoral artery in low-weight infants. An infant weighing only 7 kg with severe...
متن کاملEffectiveness of balloon valvuloplasty in the young adult with congenital aortic stenosis.
The objective of this study was to assess the effectiveness of balloon valvuloplasty in the young adult with congenital aortic stenosis and to compare its effectiveness with children. Percutaneous balloon valvuloplasty is effective in children with congenital aortic stenosis, but not in adults with acquired calcific aortic stenosis. Because effectiveness of balloon valvuloplasty in young adults...
متن کاملAortic valve reinterventions after balloon aortic valvuloplasty for congenital aortic stenosis intermediate and late follow-up.
OBJECTIVES the aim of this study was to evaluate the long-term results of transcatheter balloon aortic valvuloplasty, the preferred treatment for congenital aortic stenosis (AS). BACKGROUND aortic valve function and reintervention late after this procedure are not well characterized. METHODS from 1985 to 2008, 563 patients underwent balloon dilation for congenital AS. After excluding those ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 16 2 شماره
صفحات -
تاریخ انتشار 1990