The Electrochemical Detremination of Nitric Oxide in Seawater Media with Microelectrodes
نویسندگان
چکیده
The electrochemical determination of nitric oxide in seawater with microelectrodes is reported in this paper. Two electrodes, ISO-NOPMC microsensor and modified platinum microelectrode, are evaluated for their performance in seawater. The peak current is found to be linear with the NO concentration in the range 1×10-1.2×10 mol/l for both microelectrodes. The detection limit of ISO-NOPMC microsensor is 1.4×10 mol/l. Two methods for calibration of NO sensor, saturated NO solutions and decomposition of S-nitroso-acetyl-DL-penicillamine (SNAP), are discussed and compared. In addition, we examined the performance degradation of these microelectrodes in seawater due to complexation with seawater components.
منابع مشابه
Developed Method Application for Nitrite Ion (NO2¯ ) Analysis of Tib -186 Macrophage Like Cell Lines by Rapid Isocratic HPLC System with High Sensitive Glassy Carbon Electrochemical Detector
A rapid isocratic method of high performance liquid chromatography system (HPLC) with a glassy carbon working electrode of electrochemical detector is set up for quantitative detection of trace amount of nitrite ion (NO2¯) in aqueous protein containing cell lysate, cell media, plasma, serum, urine and other body fluids. The solid extraction reversed phase cartridges ...
متن کاملReal-time electrochemical detection of extracellular nitric oxide in tobacco cells exposed to cryptogein, an elicitor of defence responses
It was previously reported that cryptogein, an elicitor of defence responses, induces an intracellular production of nitric oxide (NO) in tobacco. Here, the possibility was explored that cryptogein might also trigger an increase of NO extracellular content through two distinct approaches, an indirect method using the NO probe 4,5-diaminofluorescein (DAF-2) and an electrochemical method involvin...
متن کاملHighly Sensitive Amperometric Sensor Based on Gold Nanoparticles Polyaniline Electrochemically Reduced Graphene Oxide Nanocomposite for Detection of Nitric Oxide
A sensitive electrochemical sensor was fabricated for selective detection of nitric oxide (NO) based on electrochemically reduced graphene (ErGO)-polyaniline (PANI)-gold nanoparticles (AuNPs) nanocomposite. It was coated on a gold (Au) electrode through stepwise electrodeposition to form AuNPs-PANI-ErGO/Au electrode. The AuNPs-PANI-rGO nanocomposite was characterized by Field Emission Scanning ...
متن کاملCarbon Fiber-based Microelectrodes and Microbiosensors
The chemically relatively inert carbon fiber (CF) has outstanding mechanical and electrical properties and provides an excellent base electrode for electrophysiological, electrochemical and biosensor applications on a micrometer or perhaps even on a submicrometer scale. CF microelectrodes have been used to record neuronal action potentials (spikes) since 1979 (Armstrong-James & Millar, 1979). T...
متن کاملبررسی نقش نیتریک اکساید در کنترل اختلالات تکاملی جنین موش در مرحله پیش لانه گزینی در محیطهای کشت حاوی گلوکز زیاد
Pregnancy in diabetic females causes delay in early stages of embryonic growth and development and higher incidence of congenital malformations and spontaneous miscarriage compared with those of non-diabetic conditions. High glucosis tratogenicity seems to be related to reduction of Nitric Oxide production (NO) in hyperglycemic condition. The goal of present work wa...
متن کامل