Advantages of inflatable multichannel endorectal applicator in the neo‐adjuvant treatment of patients with locally advanced rectal cancer with HDR brachytherapy
نویسندگان
چکیده
High-dose rate endorectal brachytherapy (HDR-EBT) is mainly used as a palliative treatment modality. In this paper, we compare dosimetry distributions for a single-channel catheter (Miami) applicator with distributions of the inflatable multichannel (Novi Sad) endorectal applicator. The comparisons were made with respect to dose coverage to the clinical tumor volume as well as to the bladder, rectal wall, prostate, and bone marrow. Our results suggest that a multichannel applicator provides better sparing of the bone marrow by 50%, clinically uninvolved parts of the rectal wall by 70%, and bladder and prostate (in the case of male patients) by 100% in terms of ratio of median doses to critical organ volume for single- and multichannel endorectal applicators. Our results justify the advantage of using a multichannel endorectal brachytherapy applicator as a neo-adjuvant treatment of patients with locally advanced rectal cancer.
منابع مشابه
Inflatable multichannel rectal applicator for adaptive image-guided endoluminal high-dose-rate rectal brachytherapy: design, dosimetric characteristics, and first clinical experiences
PURPOSE To investigate the dosimetric results and first clinical experiences with a new designed balloon applicator with adjustable catheters for endoluminal brachytherapy for patients with locally advanced rectal cancer not undergoing surgery. MATERIAL AND METHODS The applicator consists of an inflatable rectal balloon with six attached Foley catheters used as guidance for the inserted brach...
متن کاملIs Low-Dose-Rate Endorectal Brachytherapy a New Treatment Method for Locally Advanced Distal Rectal Cancer?
In the treatment of locally advanced rectal cancer, preoperative chemoradiotherapy improved the rate of local recurrence after surgery and anal sphincter preservation [1]. Because it resulted in down-staging of tumors and changes of histologic characteristics, it is now regarded as the standard treatment in the patients with stages II-III advanced rectal cancer [2]. Conventional preoperative ch...
متن کاملSingle versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning
PURPOSE To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. MATERIAL AND METHODS We randomly selected 12 patients with endometrial carcinoma, who received adjuvant vaginal cuff ...
متن کاملRectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector
Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...
متن کاملApplicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...
متن کامل