Normal values for renal length and volume as measured by magnetic resonance imaging.

نویسندگان

  • Benjamin Cheong
  • Raja Muthupillai
  • Mario F Rubin
  • Scott D Flamm
چکیده

The objective of this magnetic resonance imaging (MRI) study was to (1) test the validity of the ellipsoid formula for estimating kidney volume using ex vivo and in vivo models and (2) establish a normal range of values for kidney length and volume in patients with no known history of renal disease. The volumes of five excised porcine kidneys were measured by (1) disc-summation method, (2) ellipsoid formula, and (3) water displacement method. In a retrospective, consecutive group of clinically referred patients (n = 150; 300 kidneys), individual kidney volume and length were calculated by the disc-summation method and by multiplanar reformation of MRI data, respectively. For comparison, kidney volumes also were calculated using the ellipsoid formula in all patients. Renal volume that was obtained by MRI using the disc-summation method was within 5% of the volume that was determined by the water displacement method, independent of the spatial resolution of the MRI technique used. Data from both the in vivo and the ex vivo models revealed that the ellipsoid formula that commonly is used in ultrasonography underestimates renal volume by 17 to 29% compared with the disc-summation method (P < 0.05). As measured by MRI (mean +/- SD), kidney lengths were 12.4 +/- 0.9 cm for men and 11.6 +/- 1.1 cm for women, and kidney volumes were 202 +/- 36 ml for men and 154 +/- 33 ml for women. The results from the ex vivo MRI study show that the kidney volume that was obtained using the disc-summation method is within 5% of the true kidney volume as measured by the water displacement method. The ellipsoid formula consistently and significantly underestimates the true kidney volume. The length and the volume of kidneys that are obtained by MRI in patients with no known history of intrinsic renal disease are greater than the commonly quoted reference values that are obtained by ultrasonography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevalence and Length of Cavum Septi Pellucidi in Normal Adult Human Brains Using Magnetic Resonance Imaging

Purpose: In view of the fact that the reported prevalence of cavum septi pellucidi (CSP) in normal adult human brains varies enormously from 0.1% to 87.5% and that this prevalence has not been yet studied in Iran, this study was designed to determine the prevalence and length of CSP in normal adult human brains using magnetic resonance imaging (MRI). Materials and Methods: 29 healthy volunteer...

متن کامل

The Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging

Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...

متن کامل

Sexual Dimorphism in Volume of the Cerebral Hemispheres and Lateral Ventricles in Schizophrenia Using Magnetic Resonance Imaging

Purpose: This study is designed to determine the sexual dimorphism pattern in volume of the cerebral hemispheres and lateral ventricles in schizophrenia using magnetic resonance imaging (MRI) and to compare it with normal sexual dimorphism pattern in healthy brains. Materials and Methods: This study is performed on 29 healthy volunteers (21 males, 8 females) and 29 patients suffered from schiz...

متن کامل

Measuring Dimensions of Lumbar Intervertebral Discs in Normal Subjects

Introduction: Disc degeneration is a natural aging process characterized by changes in appearance and chemical structure of the disc. This degeneration leads to back pain. In regard to the limitation of current therapeutical methods for patients with degenerated discs, arthroplasty has been suggested as an alternative method. To manufacture artificial discs for Iranians, determining normal lumb...

متن کامل

Application of Magnetic Resonance Imaging (MRI) as a safe & Application of Magnetic Resonance Imaging (MRI) as a safe & non-destructive method for monitoring of fruit & vegetable in postharvest period

To investigate and control quality, one must be able to measure quality-related attributes. Quality of produce encompasses sensory attributes, nutritive values, chemical constituents, mechanical properties, functional properties and defects. MRI has great potential for evaluating the quality of fruits and vegetables. The equipment now available is not feasible for routine quality testing. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical journal of the American Society of Nephrology : CJASN

دوره 2 1  شماره 

صفحات  -

تاریخ انتشار 2007