Flow and wall shear stress in end-to-side and side-to-side anastomosis of venous coronary artery bypass grafts
نویسندگان
چکیده
PURPOSE Coronary artery bypass graft (CABG) surgery represents the standard treatment of advanced coronary artery disease. Two major types of anastomosis exist to connect the graft to the coronary artery, i.e., by using an end-to-side or a side-to-side anastomosis. There is still controversy because of the differences in the patency rates of the two types of anastomosis. The purpose of this paper is to non-invasively quantify hemodynamic parameters, such as mass flow and wall shear stress (WSS), in end-to-side and side-to-side anastomoses of patients with CABG using computational fluid dynamics (CFD). METHODS One patient with saphenous CABG and end-to-side anastomosis and one patient with saphenous CABG and side-to-side anastomosis underwent 16-detector row computed tomography (CT). Geometric models of coronary arteries and bypasses were reconstructed for CFD analysis. Blood flow was considered pulsatile, laminar, incompressible and Newtonian. Peri-anastomotic mass flow and WSS were quantified and flow patterns visualized. RESULTS CFD analysis based on in-vivo CT coronary angiography data was feasible in both patients. For both types of CABG, flow patterns were characterized by a retrograde flow into the native coronary artery. WSS variations were found in both anastomoses types, with highest WSS values at the heel and lowest WSS values at the floor of the end-to-side anastomosis. In contrast, the highest WSS values of the side-to-side anastomosis configuration were found in stenotic vessel segments and not in the close vicinity of the anastomosis. Flow stagnation zones were found in end-to-side but not in side-to-side anastomosis, the latter also demonstrating a smoother stream division throughout the cardiac cycle. CONCLUSION CFD analysis of venous CABG based on in-vivo CT datasets in patients was feasible producing qualitative and quantitative information on mass flow and WSS. Differences were found between the two types of anastomosis warranting further systematic application of the presented methodology on multiple patient datasets.
منابع مشابه
Comparison of the Graft Angles Effects on the Temporal Wall Shear Stress Gradients in the Aorto-Coronary and Coronary-Coronary Bypasses
In this theoretical study, the effect of various types of bypass graft angles on the flow field, has been investigated specially on the temporal Wall Shear Stress (WSS) on the toe, heel and some locations on the bed of the Left Anterior Descending (LAD) artery at the anastomoses areas in the Aorto-Coronary (AC) and Coronary-Coronary (CC) bypasses. Flow fields in both bypasses with angles of...
متن کاملFlow waveform effects on end-to-side anastomotic flow patterns.
PURPOSE Restenosis due to distal anastomotic intimal hyperplasia, a leading cause of arterial bypass graft failure, is thought to be promoted by hemodynamic effects, specifically 'abnormal' wall shear stress patterns. The purpose of this study was to quantify the effects of flow waveform on peri-anastomotic flow and wall shear stress patterns. METHODS Blood flow and wall shear stress patterns...
متن کاملComparison of blood-flow velocity waveforms in different coronary artery bypass grafts. Sequential saphenous vein grafts and internal mammary artery grafts.
Characteristics of blood-flow velocities were investigated at different sites in two types of coronary artery bypass grafts, sequential saphenous vein grafts (SSVG) and internal mammary artery grafts (IMAG). The latter appear to have the longest life span. The patency rate of the side-to-side anastomosis of the SSVG is better than that of the end-to-side anastomosis. The SSVG was anastomosed to...
متن کاملDifferent Coronary Artery Bypass Grafts Sequential Saphenous Vein Grafts and Internal Mammary Artery Grafts
Characteristics of blood-flow velocities were investigated at different sites in two types of coronary artery bypass grafts, sequential saphenous vein grafts (SSVG) and internal mammary artery grafts (IMAG). The latter appear to have the longest life span. The patency rate of the side-to-side anastomosis of the SSVG is better than that of the end-to-side anastomosis. The SSVG was anastomosed to...
متن کاملComparison of Blood-Flow Velocity Waveforms
Characteristics of blood-flow velocities were investigated at different sites in two types of coronary artery bypass grafts, sequential saphenous vein grafts (SSVG) and internal mammary artery grafts (IMAG). The latter appear to have the longest life span. The patency rate of the side-to-side anastomosis of the SSVG is better than that of the end-to-side anastomosis. The SSVG was anastomosed to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BioMedical Engineering OnLine
دوره 6 شماره
صفحات -
تاریخ انتشار 2007