Position-sensitive ion detection in precision Penning trap mass spectrometry
نویسندگان
چکیده
A commercial, position-sensitive ion detector was used for the rst time for the time-ofight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.
منابع مشابه
A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملRamsey method of separated oscillatory fields for high-precision penning trap mass spectrometry.
Ramsey's method of separated oscillatory fields is applied to the excitation of the cyclotron motion of short-lived ions in a Penning trap to improve the precision of their measured mass values. The theoretical description of the extracted ion-cyclotron-resonance line shape is derived and its correctness demonstrated experimentally by measuring the mass of the short-lived 38Ca nuclide with an u...
متن کاملPenning trap mass measurements with stored and cooled exotic ions
The technique of Penning trap mass spectrometry is briefly reviewed particularly in view of precision experiments on unstable nuclei, performed at different facilities worldwide. Selected examples of recent results emphasize the importance of high-precision mass measurements in various fields of physics. PACS numbers: 07.75.+h, 21.10.Dr, 32.10.Bi Submitted to: J. Phys. B: At. Mol. Opt. Phys. Hi...
متن کاملPreparing isomerically pure beams of short-lived nuclei at JYFLTRAP
A new procedure to prepare isomerically clean samples of ions with a mass resolving power of more than 1×10 has been developed at the JYFLTRAP tandem Penning trap system. The method utilises a dipolar rf-excitation of the ion motion with separated oscillatory fields in the precision trap. During a subsequent retransfer to the purification trap, the contaminants are rejected and as a consequence...
متن کامل