Fluoroscopy for transpedicular screw placement in scoliosis: to what extent can radiation exposure be reduced by the freehand technique?

نویسندگان

  • Tolga Ege
  • Serkan Bilgic
  • Kenan Koca
  • Erbil Oguz
  • Erden Kilic
  • Ozkan Kose
  • Ali Sehırlıoglu
  • Atilla Kazanci
  • Omer Ersen
چکیده

AIM In spinal surgery, high doses of radiation are delivered during surgical procedures that require fluoroscopic control. The aim of this study was to determine the amount of radiation delivered from the fluoroscopic unit and also the factors to reduce the amount of radiation during the surgery of adolescent idiopathic scoliosis patients. MATERIAL AND METHODS In this retrospective study 21 patients with adolescent idiopathic scoliosis treated by transpedicular screws between 2009 and 2012 were enrolled the study. Dose Area Product (DAP) values , number of views obtained during screw placement and other data were retrieved from the medical records of the patients. RESULTS The mean number of transpedicular screws used was 18. An average of 10,1 vertebrae were instrumented. The mean number of images obtained was 7.76. Mean fluoroscopy time was 7.95 seconds. The total mean DAP was 64.6 cGy.cm < sup > 2 < /sup > . CONCLUSION The amount of ionizing radiation transmitted to the patient and the surgical team can be reduced by freehand insertion, confirmation of screw position by AP and lateral fluoroscopic views including more than one segment, the use of K-wires as a guide in spinal segments with abnormal pedicular anatomy and neuromonitorization of the patient during the surgical correction of adolescent idiopathic scoliosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Fluoroscopy for transpedicular screw placement in scoliosis: what is the best method of measuring radiation exposure?

We congratulate the authors for reporting their results. Ege et al. have shared their results that they got from the fluoroscopy device retrospectively. We think that this study method could not prove the exact amount of radiation exposure that impacts the surgical team correctly. The authors compare their study with similar studies (2, 3) that measure radiation exposure by dosimetry as more ob...

متن کامل

Modified Mini-open Transforaminal Lumbar Interbody Fusion

STUDY DESIGN Retrospective case series. OBJECTIVE To describe a modified technique for mini-open transforaminal lumbar interbody fusion (TLIF) that improves visualization for decompression, fusion, and freehand pedicle screw insertion. Accuracy of freehand pedicle screw placement with this technique was assessed. SUMMARY OF BACKGROUND DATA Mini-open TLIF is a minimally invasive technique th...

متن کامل

Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques.

OBJECTIVE The purpose of this study was to prospectively evaluate the clinical utility and accuracy of intraoperative three-dimensional fluoroscopy as an adjunct for the placement of a complex spinal instrumentation. METHODS The Siemens Iso-C three-dimensional fluoroscopy unit in the combination with the Stealth Treon computer volumetric navigational system was used. A total of 279 spinal ins...

متن کامل

Freehand Thoracic Pedicle Screw Placement: Review of Existing Strategies and a Step-by-Step Guide Using Uniform Landmarks for All Levels

Pedicle screw fixation in the thoracic spine presents certain challenges due to the critical regional neurovascular anatomy as well as the narrow pedicular corridor that typically exists. With increased awareness of the dangers of intraoperative radiation, the ability to place pedicle screws with anatomic landmarks alone is paramount. In this study, we reviewed the literature from 1990 to 2015 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Turkish neurosurgery

دوره 23 3  شماره 

صفحات  -

تاریخ انتشار 2013