Predictors of severe right ventricular failure after implantable left ventricular assist device insertion: analysis of 245 patients.
نویسندگان
چکیده
BACKGROUND Insertion of an implantable left ventricular assist device (LVAD) complicated by early right ventricular (RV) failure has a poor prognosis and is largely unpredictable. Prediction of RV failure after LVAD placement would lead to more precise patient selection and optimal device selection. METHODS AND RESULTS We reviewed data from 245 patients (mean age, 54+/-11 years; 85% male) with 189 HeartMate (77%) and 56 Novacor (23%) LVADs. Ischemic cardiomyopathy predominated (65%), and 29% had dilated cardiomyopathy. Overall, RV assist device (RVAD) support was required after LVAD insertion for 23 patients (9%). We compared clinical and hemodynamic parameters before LVAD insertion between RVAD (n=23) and No-RVAD patients (n=222) to determine preoperative risk factors for severe RV failure. By univariate analysis, female gender, small body surface area, nonischemic etiology, preoperative mechanical ventilation, circulatory support before LVAD insertion, low mean and diastolic pulmonary artery pressures (PAPs), low RV stroke work (RVSW), and low RVSW index (RVSWI) were significantly associated with RVAD use. Elevated PAP and pulmonary vascular resistance were not risk factors. Risk factors by multivariable logistic regression were preoperative circulatory support (odds ratio [OR], 5.3), female gender (OR, 4.5), and nonischemic etiology (OR, 3.3). CONCLUSIONS The need for circulatory support, female gender, and nonischemic etiology were the most significant predictors for RVAD use after LVAD insertion. Regarding hemodynamics, low PAP and low RVSWI, reflecting low RV contractility, were important parameters. This information may lead to better patient selection for isolated LVAD implantation.
منابع مشابه
Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملRight ventricular failure after left ventricular assist device insertion: preoperative risk factors.
Right ventricular failure after left ventricular assist device placement is the major concern on weaning from cardiopulmonary bypass and it is one of the most serious complications in the postoperative period. This complication has a poor prognosis and is generally unpredictable. The identification of pre-operative risk factor for this serious complication is incomplete yet. In order to determi...
متن کاملRight ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.
OBJECTIVE The aim of this study was to evaluate the incidence, risk factors, and effect on outcomes of right ventricular failure in a large population of patients implanted with continuous-flow left ventricular assist devices. METHODS Patients (n = 484) enrolled in the HeartMate II left ventricular assist device (Thoratec, Pleasanton, Calif) bridge-to-transplantation clinical trial were exami...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 106 12 Suppl 1 شماره
صفحات -
تاریخ انتشار 2002