[Determination method of tricresyl phosphate in polyvinyl chloride].
نویسندگان
چکیده
A simple and rapid method using HPLC was developed for the determination of tricresyl phosphate (TCP) in polyvinyl chloride (PVC) articles. A test sample was extracted with acetonitrile at 37 degrees C overnight. The extract solution diluted with an equivalent amount of water was applied to a Sep-Pak C18 cartridge, and TCP was eluted with acetonitrile-water (2:1) mixture. The eluate was analyzed by HPLC with an Inertsil Ph-3 column, using 65% acetonitrile/water as the mobile phase, with UV detection (264 nm). The calibration curve was rectilinear from 0.5 to 100 micrograms/mL. The recoveries of TCP added to various kinds of PVC articles at the level of 1,000 micrograms/g were 84.7-98.6%. The determination limit of TCP was 50 micrograms/g in samples. This method was applied to products including 3.1, 6.6 and 8.8% TCP and the recoveries of TCP were 87.3-91.4%. This method is very simple, and it seems suitable for a regulatory test.
منابع مشابه
Portable and remote electrochemical sensing system for detection of tricresyl phosphate in gas phase
A portable electrochemical sensor has been developed for determination of tricresyl phosphate (TCP) in gas phase. An alkaline catalyst column was used in an automatic TCP sampling system where gasified TCP was hydrolysed to cresol, making it electrochemically detectable. Hydrolysates were then detected in the flow injection analysis (FIA). Amperometric measurements were performed utilizing the ...
متن کاملTricresyl phosphate in polyvinylchloride gloves: a new allergen.
Marie-Noëlle Crépy1,2, Eddy Langlois3, Sandrine Mélin3, Alexis Descatha1, Lynda Bensefa-Colas2, Anne-Marie Jonathan1 and Jacques Ameille1 1Department of Occupational Health, AP-HP, Groupe Hospitalier Raymond Poincaré, 92380 Garches, France, 2Department of Occupational Health, AP-HP, Groupe Hospitalier Cochin, 75014 Paris, France, and 3 Institut national de recherche et sécurité, Analytical Orga...
متن کاملVoltammetric determination of the neonicotinoid insecticide thiamethoxam using a tricresyl phosphate-based carbon paste electrode
The objective of the work was to investigate the possibility of using a tricresyl phosphate-based carbon paste electrode for the direct voltammetric determination of the neonicotinoid insecticide thiamethoxam. The analyte was determined by differential pulse voltammetry in Britton–Robinson buffer pH 7.0 in the concentration range of 3.72–41.5 μg mL-1. The reproducibility of the analytical signa...
متن کاملPreparation of Oxygen Meter Based Biosensor for Determination of Triglyceride in Serum
A method is described for preparation of a dissolved oxygen meter (make Aqualytic, Germany) based triglyceride biosensor employing a polyvinyl chloride (PVC) membrane bound lipase, glycerol kinase (GK) and glycerol-3-phosphate oxidase The biosensor measures dissolved O2 utilized in the oxidation of triglyceride (TG) by membrane bound lipase, glycerol kinase (GK) and glycerol-3-phosphate oxidase...
متن کاملCovalent immobilization of lipase, glycerol kinase, glycerol-3-phosphate oxidase & horseradish peroxidase onto plasticized polyvinyl chloride (PVC) strip & its application in serum triglyceride determination
BACKGROUND & OBJECTIVES Reusable biostrip consisting enzymes immobilized onto alkylamine glass beads affixed on plasticized PVC strip for determination of triglyceride (TG) suffers from high cost of beads and their detachments during washings for reuse, leading to loss of activity. The purpose of this study was to develop a cheaper and stable biostrip for investigation of TG levels in serum. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Shokuhin eiseigaku zasshi. Journal of the Food Hygienic Society of Japan
دوره 44 1 شماره
صفحات -
تاریخ انتشار 2003