Correcting for motion artifact in handheld laser speckle images.

نویسندگان

  • Ben Lertsakdadet
  • Bruce Y Yang
  • Cody E Dunn
  • Adrien Ponticorvo
  • Christian Crouzet
  • Nicole Bernal
  • Anthony J Durkin
  • Bernard Choi
چکیده

Laser speckle imaging (LSI) is a wide-field optical technique that enables superficial blood flow quantification. LSI is normally performed in a mounted configuration to decrease the likelihood of motion artifact. However, mounted LSI systems are cumbersome and difficult to transport quickly in a clinical setting for which portability is essential in providing bedside patient care. To address this issue, we created a handheld LSI device using scientific grade components. To account for motion artifact of the LSI device used in a handheld setup, we incorporated a fiducial marker (FM) into our imaging protocol and determined the difference between highest and lowest speckle contrast values for the FM within each data set (Kbest and Kworst). The difference between Kbest and Kworst in mounted and handheld setups was 8% and 52%, respectively, thereby reinforcing the need for motion artifact quantification. When using a threshold FM speckle contrast value (KFM) to identify a subset of images with an acceptable level of motion artifact, mounted and handheld LSI measurements of speckle contrast of a flow region (KFLOW) in in vitro flow phantom experiments differed by 8%. Without the use of the FM, mounted and handheld KFLOW values differed by 20%. To further validate our handheld LSI device, we compared mounted and handheld data from an in vivo porcine burn model of superficial and full thickness burns. The speckle contrast within the burn region (KBURN) of the mounted and handheld LSI data differed by <4  %   when accounting for motion artifact using the FM, which is less than the speckle contrast difference between superficial and full thickness burns. Collectively, our results suggest the potential of handheld LSI with an FM as a suitable alternative to mounted LSI, especially in challenging clinical settings with space limitations such as the intensive care unit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser Speckle Reduction based on electroactive polymers

Optotune has developed an Electroactive Polymer Actuator-based solution to move a diffuser and drastically reduce the speckle contrast of Laser beams: the LSR-5-17 (Laser Speckle Reducer). With its integrated miniaturized electronics for HV generation and motion control, the LSR-5-17 provides a compact 27 x 21 x 6mm solution with a simple 5V micro USB interface for power supply. A miniaturized ...

متن کامل

Handheld, point-of-care laser speckle imaging.

Laser speckle imaging (LSI) enables measurement of relative changes in blood flow in biological tissues. We postulate that a point-of-care form factor will lower barriers to routine clinical use of LSI. Here, we describe a first-generation handheld LSI device based on a tablet computer. The coefficient of variation of speckle contrast was <2% after averaging imaging data collected over an acqui...

متن کامل

Temperature Mapping Using Ultrasound Digital Images

Introduction:  The  success  of  hyperthermia  depends  on  the  accuracy  of  the  temperature  monitoring in the tumor and the surrounding normal tissue. In this study, the temperature changes  were determined by computing the speckle displacement in the ultrasound digital images. Speckle  tracking algorithm was used to compute the displacement.  Materials and Methods: The experiment was perf...

متن کامل

A Novel Approach to Overcome Movement Artifact When Using a Laser Speckle Contrast Imaging System for Alternating Speeds of Blood Microcirculation

The laser speckle contrast imager (LSCI) provides a powerful yet simple technique for measuring microcirculatory blood flow. Ideal for blood dynamic responses, the LSCI is used in the same way as a conventional Laser Doppler Imager (LDI). However, with a maximum skin depth of approximately 1 mm, the LSCI is designed to focus on mainly superficial blood flow. It is used to measure skin surface a...

متن کامل

Speckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images

Introduction One of the most important pre-processing steps in optical coherence tomography (OCT) is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 23 3  شماره 

صفحات  -

تاریخ انتشار 2018