The impact of reconstruction and scanner characterisation on the diagnostic capability of a normal database for [123I]FP-CIT SPECT imaging
نویسندگان
چکیده
BACKGROUND The use of a normal database for [123I]FP-CIT SPECT imaging has been found to be helpful for cases which are difficult to interpret by visual assessment alone, and to improve reproducibility in scan interpretation. The aim of this study was to assess whether the use of different tomographic reconstructions affects the performance of a normal [123I]FP-CIT SPECT database and also whether systems benefit from a system characterisation before a database is used. Seventy-seven [123I]FP-CIT SPECT studies from two sites and with 3-year clinical follow-up were assessed quantitatively for scan normality using the ENC-DAT normal database obtained in well-documented healthy subjects. Patient and normal data were reconstructed with iterative reconstruction with correction for attenuation, scatter and septal penetration (ACSC), the same reconstruction without corrections (IRNC), and filtered back-projection (FBP) with data quantified using small volume-of-interest (VOI) (BRASS) and large VOI (Southampton) analysis methods. Test performance was assessed with and without system characterisation, using receiver operating characteristics (ROC) analysis for age-independent data and using sensitivity/specificity analysis with age-matched normal values. The clinical diagnosis at follow-up was used as the standard of truth. RESULTS There were no significant differences in the age-independent quantitative assessment of scan normality across reconstructions, system characterisation and quantitative methods (ROC AUC 0.866-0.924). With BRASS quantification, there were no significant differences between the values of sensitivity (67.4-83.7%) or specificity (79.4-91.2%) across all reconstruction and calibration strategies. However, the Southampton method showed significant differences in sensitivity between ACSC (90.7%) vs IRNC (76.7%) and FBP (67.4%) reconstructions with calibration. Sensitivity using ACSC reconstruction with this method was also significantly better with calibration than without calibration (65.1%). Specificity using the Southampton method was unchanged across reconstruction and calibration choices (82.4-88.2%). CONCLUSIONS The ability of a normal [123I]FP-CIT SPECT database to assess clinical scan normality is equivalent across all reconstruction, system characterisation, and quantification strategies using BRASS quantification. However, when using the Southampton quantification method, performance is sensitive to the reconstruction and calibration strategy used.
منابع مشابه
Improvement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database
Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the util...
متن کاملValidation of Optimum ROI Size for 123I-FP-CIT SPECT Imaging Using a 3D Mathematical Cylinder Phantom
Objective(s): The partial volume effect (PVE) of single-photon emission computed tomography (SPECT) on corpus striatum imaging is caused by the underestimation of specific binding ratio (SBR). A large ROI (region of interest) set using the Southampton method is independent of PVE for SBR. The present study aimed to determine the optimal ROI size with contrast and SBR for striatum images and val...
متن کاملAutopsy validation of 123I-FP-CIT dopaminergic neuroimaging for the diagnosis of DLB
OBJECTIVE To conduct a validation study of 123I-N-fluoropropyl-2b-carbomethoxy-3b-(4-iodophenyl) nortropane (123I-FP-CIT) SPECT dopaminergic imaging in the clinical diagnosis of dementia with Lewy bodies (DLB) with autopsy as the gold standard. METHODS Patients >60 years of age with dementia who had undergone 123I-FP-CIT imaging in research studies and who had donated their brain tissue to th...
متن کاملAccurate differentiation of parkinsonism and essential tremor using visual assessment of [123I]-FP-CIT SPECT imaging: the [123I]-FP-CIT study group.
OBJECTIVE To evaluate whether visual assessment of [123I]-FP-CIT (DaTSCAN, Nycomed Amersham, plc) single photon emission computerized tomography (SPECT) images can differentiate between parkinsonism and essential tremor (ET). METHODS [123I]-FP-CIT SPECT imaging was conducted in a six-center study of 158 patients with a clinical diagnosis of parkinsonism compared with 27 ET cases and 35 health...
متن کامل123I-FP-CIT brain SPECT (DaTSCAN) imaging in the diagnosis of patients with movement disorders--first results.
BACKGROUND/AIM 123I-FP-CIT brain single-photon emission computed tomography (SPECT), DaTSCAN imaging, offers a possibility to study structural and biochemical integrity of presinaptic dopaminergic neurotransmitter system. The aim of this study was to evaluate the usefulness of 123I-FP-CIT brain SPECT scintigraphy in patients with extrapyramidal diseases. METHODS Fifteen patients (8 males and ...