An Investigation of the Current Distribution in an HTS Triaxial Power Cable and its Operational Impacts on a Power System

نویسندگان

  • Aly Fathy
  • Michael J. Gouge
  • Anne Mayhew
  • Marcus Aaron Young
چکیده

An investigation of the current distribution in a 3-phase triaxial superconducting cable was conducted to study the phase imbalance under steady-state operation and to assist in the construction of a transient model to study operational impacts in a power grid. The triaxial cable consisted of three superconducting concentric phases inside a copper shield, with each phase composed of multiple layers of BSCCO tape wound helically in opposite directions. Current distribution within the cable was determined by using an electric circuit (EC) model containing the self and mutual inductances resulting from both axial and tangential magnetic fields. An AC loss term was also included in the model. Building on the EC model, a lumped cable model was used to investigate the effects of the triaxial cable on a power grid when faults are applied to the system. Cable lengths for future applications (~16 km) were considered. Steady-state simulation of the EC model revealed that the electrical imbalance associated with the phases of the triaxial cable may be negligible for cable lengths less than one mile, but become more of a concern at greater lengths. Transient simulations showed that fault currents approaching 30 kApeak may be possible under certain conditions and that resulting induced shield currents may be substantial. Recommendations for further research are provided as well as possible suggestions for alleviating the electrical imbalance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tri-axial Core Design of a Distribution System Class HTS Power Cable

A tri-axial HTS power cable has been proposed and developed to reduce the number of HTS wires because it has copper shield instead of HTS shield. However, it has a drawback which is an inherent imbalance problem due to an asymmetry configuration in the cable. The authors designed a 22.9 kV/50 MVA class tri-axial HTS cable. The inherent imbalance problem of the three-phase currents in the tri-ax...

متن کامل

A Mixed Integer Programming Approach to Optimal Feeder Routing for Tree-Based Distribution System: A Case Study

A genetic algorithm is proposed to optimize a tree-structured power distribution network considering optimal cable sizing. For minimizing the total cost of the network, a mixed-integer programming model is presented determining the optimal sizes of cables with minimized location-allocation cost. For designing the distribution lines in a power network, the primary factors must be considered as m...

متن کامل

Optimization of an HTS Induction/Synchronous Motor According to Changing of HTS Tapes Critical Current by Analytical Hierarchy Process

This paper represents the performance of a squirrel-cage High Temperature Superconducting Induction/ Synchronous Motor (HTS-ISM) based on nonlinear electrical equivalent circuit. The structure of the HTS-ISM is the same as that of the squirrel-cage type induction machine, and the secondary windings are fabricated by the use of the HTS wires. It has already been shown that based on the experimen...

متن کامل

The Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System

In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...

متن کامل

An Ultra High CMRR Low Voltage Low Power Fully Differential Current Operational Amplifier (COA)

this paper presents a novel fully differential (FD) ultra high common mode rejection ratio (CMRR) current operational amplifier (COA) with very low input impedance. Its FD structure that attenuates common mode signals over all stages grants ultra high CMRR and power supply rejection ratio (PSRR) that makes it suitable for mixed mode and accurate applications. Its performance is verified by HSPI...