PURPOSE Because of the potential usefulness of evaluating and treating choroidal neovascularization obscured by blood, we designed this study to quantify the transmission of dye fluorescence and laser energy through blood. METHODS Blood preparations anticoagulated with ethylenediaminetetraacetic acid with hematocrits of 0% (plasma), 46%, and 99% were placed in open cuvettes with path lengths of 100, 200, or 500 microns and were exposed for one minute to either 100% oxygen or 100% carbon dioxide. Each cuvette was then sealed. Photographs of the cuvettes of blood in front of a flask of fluorescein or indocyanine green solution were decoded and used to calculate the percent transmission of fluorescence through blood. Cuvettes of blood were also placed in the path of argon, krypton, and diode lasers for energy transmission measurements. RESULTS Plasma transmission of fluorescein and indocyanine green fluorescence and argon, krypton, and diode laser energy was 89% to 100% for all samples tested. Transmission of fluorescein fluorescence and argon laser energy through 99% hematocrit samples were both less than 5%. Transmission of indocyanine green fluorescence through 100-, 200-, and 500-microns-thick cuvettes filled with 99% hematocrit blood was 57%, 34%, and 4%. Transmission of krypton laser energy was 50%, 25%, and 6%; and transmission of diode laser energy was 60%, 35%, and 12% through 99% hematocrit blood. Intermediate transmission values were obtained for 46% hematocrit samples. CONCLUSIONS Krypton and, to a slightly greater degree, diode laser energy penetrate a thin film of blood. Indocyanine green fluorescence also penetrates a thin film of blood. If a layer of blood appears thinner than 500 microns, then indocyanine green angiography may be useful in imaging underlying pathologic features. If a lesion can be imaged with indocyanine green, then it can probably be treated with a krypton or diode laser.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

1.7MW Nd:YAG Laser Pulse Generation by A Passive BDN Q-switch

This paper describes the passive Qswitch, based on polymer and organic dye BDN, of a pulsed Nd:YAG laser. Pulses of 27ns duration and peak power of 1.7MW for initial transmission of Q-switch 18.4% 0 T = have been obtained. We have obtained Q-switching efficiency of 77% for train of pulses of 31 and 76.2% 0 T = at the pump energy of 98J. We have also obtained the dependency of laser pulse charac...

متن کامل

Feasibility of blood flow measurement by externally controlled dye delivery.

We are developing a new method of delivering substances locally and repeatedly in the retinal vasculature under external control. This delivery system is based on encapsulating the substance in heat-sensitive lipsomes, which are injected intravenously and lysed by a heat pulse delivered by a laser. The feasibility of using this system with dyes and creating a sharp dye front was tested in vitro...

متن کامل

Enhanced fluorescence from arrays of nanoholes in a gold film.

Arrays of sub-wavelength holes (nanoholes) in gold films were used as a substrate for enhanced fluorescence spectroscopy. Seven arrays of nanoholes with distinct periodicities (distances between the holes) were fabricated. The arrays were then spin-coated with polystyrene films containing different concentrations of the fluorescent dye oxazine 720. The dye was excited via resonant extraordinary...

متن کامل

Optical Spectroscopic Methods to Discriminate in-Vitro Hodgkin Cancerous and Normal Tissues

Simultaneous laser induced- breakdown spectroscopy (LIBS) and acoustic response techniques as well as Laser induced fluorescence (LIF) are applied to investigate the abnormal lymph tissues due to Hodgkin disease. The spectral shift in the emissive fluorescence of the cancerous tissues has been observed respect to the normal ones. Regarding LIBS, the concentrations of Ca and Na trace elements ha...

متن کامل

The Effects of in vitro Target Compression Modulus on Laser Thrombolytic Ablation Rate

Laser thrombolysis is under investigation as a safe and rapid therapy for arterial recanalization in acute embolic stroke. Clot formation is a complex process affected by many factors that lead to differences in strength and hemoglobin concentration in samples formed from whole blood. The strength of thrombus formed in vivo also varies with age. Laser thrombolysis experiments were performed usi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of ophthalmology

دوره 119 4  شماره 

صفحات  -

تاریخ انتشار 1995