Primary stability of cementless threaded acetabular cups at first implantation and in the case of revision regarding micromotions as indicators.
نویسندگان
چکیده
The primary stability of cementless total hip endoprosthesis is of vital importance for proximate, long-term osteointegration. The extent of micromotions between implant and acetabulum is an indicator of primary stability. Based on this hypothesis, different cementless hip joint endoprosthesis were studied with regard to their micromotions. The primary stability of nine different cementless threaded acetabular cups was studied in an experimental setup with blocks of rigid foam. The micromotions between implant and implant bearing were therefore evaluated under cyclic, sinusoidal exposure. The blocks of polymer foam were prepared according to the Paprosky defect classifications. The micromotions increased with the increasing degree of the defect with all acetabuli tested. Occasionally coefficients of over 200 μm were measured. From a defect degree of 3b according to Paprosky, the implants could no longer be appropriately placed. The exterior form of the spherical implants tended to exhibit better coefficients than the conical/parabolic implants.
منابع مشابه
Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملDoes osteoporosis reduce the primary tilting stability of cementless acetabular cups?
BACKGROUND Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested. METHODS The maximum tilting moment fo...
متن کاملCementless acetabular components.
Four hundred and fifteen patients with cementless acetabular components of either a smooth threaded (130) or porous surfaced (285) variety were compared for clinical symptoms and radiographic signs of component loosening. At a mean 4.8 year follow-up none of the patients with porous acetabular components had signs of component instability. At a mean 3.9 year follow-up 27 (21%) of the patients w...
متن کامل[Mid-term results of cementless ultima cups in primary total hip replacement].
PURPOSE OF THE STUDY To present the results of primary total hip arthroplasty (THA) with use of the hemispheric threaded Ultima cup at 8.5-year follow-up. MATERIAL Between 1996 and 1999, a total of 40 Ultima acetabular components were used in 33 patients (15 men and 18 women). The average age at the time of surgery was 61.2 years (range, 45 to 71). By the end of 2006, 36 cups were assessed. I...
متن کاملUnsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis.
A high incidence of acetabular osteolysis (43%), associated with osteolytic lesions in the proximal femur (22.6%) and leading to a high revision rate, was experienced with the Omnifit total hip prosthesis. We reviewed the clinical and radiological results with 429 Omnifit total hips in 356 patients after a mean follow-up of 60 months. Time to revision and wear of the polyethylene liner with dif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedizinische Technik. Biomedical engineering
دوره 57 3 شماره
صفحات -
تاریخ انتشار 2012