Clinical performance of the EMIT vancomycin assay.

نویسندگان

  • K T Yeo
  • W Traverse
  • G L Horowitz
چکیده

In evaluating the EMIT system for vancomycin used in the Cobas Bio centrifugal analyzer, we found two potential problems, each of which may have important clinical ramifications. First, precision, though acceptable in concentrations up to 30 mg/L, was marginal in the range above 30 mg/L. Second, when EMIT values were compared with those by fluorescent polarization immunoassay (TDx), we found a good correlation but a significant proportional bias: [EMIT] = (0.877)[TDx] + 0.435 mg/L (r = 0.971). The proportional bias was much more pronounced in specimens with high creatinine values than in specimens with normal values for creatinine. It remains to be determined which method is more nearly accurate. This imprecision and proportional bias in specimens with increased creatinines lead us to conclude that the EMIT vancomycin system should be used with caution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frequency of Vancomycin-Resistant Enterococci isolated from clinical samples of Shahid Mohammadi hospital through the E-test method

Introduction: Enterococci are gram-positive coccoid bacteria that are present in the normal flora of the gastrointestinal tract in human, and many mammals and birds, as well as the environment. Vancomycin-resistant Enterococci (VRE) are a major and rising problem in hospitals throughout the world. The present study aimed to investigate the frequency of strains of Enterococci and the pattern of ...

متن کامل

Analytical Performance Evaluation of EMIT#{174} II Monoclonal Amphetamine/ Methamphetamine Assay: More Specificitythan EMIT#{174} d.a.u.TMMonoclonal Amphetamine/Methamphetamine Assay

We evaluated a new EMIT#{174} II monoclonal amphetamine! methamphetamine assay for screening human urine by comparing itwith the EMIT#{174} d.a.u. monoclonal amphetamine/methamphetamine assay and a fluorescence polarization assay. The EMIT II assay has a cutoff of 1 mg!L d-methamphetamine. The EMIT II and EMIT d.a.u. assays were run on a BM/Hitachi 704 analyzer; for the fluorescence polarizatio...

متن کامل

Buflomedil interference with the monoclonal EMIT d.a.u. amphetamine/methamphetamine immunoassay.

The interference of buflomedil with the monoclonal and polyclonal EMIT d.a.u. amphetamine immunoassays was investigated. Urine samples collected from 20 patients taking 600 mg of buflomedil daily gave false positive results with the monoclonal EMIT d.a.u. assay, as did urine specimens collected 2 hours after the first oral dose of buflomedil. Conversely, no false positive results occurred with ...

متن کامل

Correlation of the "EMIT" urine barbiturate assay with a spectrophotometric serum barbiturate assay in suspected overdose.

A rapid method for determining the presence of barbiturate in serum has been needed for some time. Presently used methods are all relatively time-consuming. A rapid immunoassay for the detection of barbiturate in urine, the “Enzyme Multiplied Immunoassay Technique” (EMIT), has recently become available. We have compared results of the EMIT urine assay with results of a spectrophotometric assay ...

متن کامل

Evaluation of commercial assays for vancomycin and aminoglycosides in serum: a comparison of accuracy and precision based on external quality assessment.

OBJECTIVE To compare the accuracy and precision of commercial assay techniques in the measurement of gentamicin, tobramycin, amikacin, netilmicin and vancomycin in serum. METHODS Data from the measurement of 40 external quality assessment samples from 358 laboratories providing a therapeutic drug monitoring service were analysed. RESULTS Significant differences between techniques in accurac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 7  شماره 

صفحات  -

تاریخ انتشار 1989