TEG® and RapidTEG® are unreliable for detecting warfarin-coagulopathy: a prospective cohort study
نویسندگان
چکیده
BACKGROUND Thromboelastography® (TEG) utilizes kaolin, an intrinsic pathway activator, to assess clotting function. Recent published studies suggest that TEG results are commonly normal in patients receiving warfarin, despite an increased International Normalized Ratio (INR). Because RapidTEG™ includes tissue factor, an extrinsic pathway activator, as well as kaolin, we hypothesized that RapidTEG would be more sensitive in detecting a warfarin-effect. METHODS Included in this prospective study were 22 consecutive patients undergoing elective cardioversion and receiving warfarin. Prior to cardioversion, blood was collected to assess INR, Prothrombin Time, TEG, and RapidTEG. RESULTS INR Results: 2.8 ± 0.5 (1.6 to 4.2). Prothrombin Time Results: 19.1 ± 2.2 (13.9. to 24.3).TEG Results (Reference Range): R-Time: 8.3 ± 2.7 (2-8); K-Time: 2.1 ± 1.4 (1-3); Angle: 62.5 ± 10.3 (55-78); MA: 63.2 ± 10.3 (51-69); G: 9.4 ± 3.5 (4.6-10.9); R-Time within normal range: 10 (45.5%) with INR 2.9 ± 0.3; Correlation coefficients for INR and each of the 5 TEG variables were insignificant (P > 0.05).RapidTEG Results (Reference Range): ACT: 132 ± 58 (86-118); K-Time: 1.2 ± 0.5 (1-2); Angle: 75.4 ± 5.2 (64-80); MA: 63.4 ± 5.1 (52-71); G: 8.9 ± 2.0 (5.0-11.6); ACT within normal range: 9 (40.9%) with INR 2.7 ± 0.5; Correlation coefficients for INR and each of the 5 RapidTEG variables were insignificant (P > 0.05). CONCLUSIONS TEG, using kaolin activation, and RapidTEG, with kaolin and tissue factor activation, were normal in a substantial percent of warfarin patients, despite an increased INR. The false-negative rate for detecting warfarin coagulopathy with either test is unacceptable. The lack of correlation between INR and all TEG and RapidTEG components further indicates that these methodologies are insensitive to warfarin effects. Findings suggest that intrinsic pathway activation may mitigate detection of an extrinsic pathway coagulopathy.
منابع مشابه
The Role of Thrombelastography in Multiple Trauma
Hemorrhage and traumatic coagulopathyis are major causes of early death in multiply injured patients. Thrombelastography (TEG) seems to be a fast and accurate coagulation test in trauma care. We suggest that multiply injured trauma patients would benefit the most from an early assessment of coagulation by TEG, mainly RapidTEG, to detect an acute traumatic coagulopathy and especially primary fib...
متن کاملIn vivo bleeding time and in vitro thrombelastography measurements are better indicators of dilutional hypothermic coagulopathy than prothrombin time.
BACKGROUND The coagulopathy of trauma is generally confirmed by prothrombin time (PT) > or =16 seconds or an international normalized ratio > or =1.5. However, the utility of these values as a screening test is unknown. We examined different coagulation tests to determine the best predictor of coagulopathic bleeding and mortality in a small animal hemorrhage model. METHODS Coagulopathy was in...
متن کاملP-95: Flow Cytometry Analysis of Bovine Semen:A Qualitative Study
Background: Although AI practices have been introduced little over 60 years, the success rate remains relatively low. This might be due to the exclusive selection of semen based on motility analysis. Recent advancement in sperm sexing using flow cytometry with an increased throughput from next generation cell sorters, made use of this technology in studding sperm qualitative aspects other than ...
متن کاملEffect of thromboelastography (TEG®) and rotational thromboelastometry (ROTEM®) on diagnosis of coagulopathy, transfusion guidance and mortality in trauma: descriptive systematic review
INTRODUCTION The understanding of coagulopathies in trauma has increased interest in thromboelastography (TEG®) and thromboelastometry (ROTEM®), which promptly evaluate the entire clotting process and may guide blood product therapy. Our objective was to review the evidence for their role in diagnosing early coagulopathies, guiding blood transfusion, and reducing mortality in injured patients. ...
متن کاملExtraction of Zn, Mn and Co from Zn-Mn-Co-Cd-Ni containing solution using D2EHPA, CYANEX® 272 and CYANEX® 302
Effects of pH, D2EHPA, Cyanex® 302 and Cyanex® 272 on extractions of zinc, manganese and cobalt from a Zn-Mn-Co-Cd-Ni containing solution was comprehensively investigated at the room temperature. The addition of Cyanex® 302 indicated a left-shifting-effect on the extraction curve of zinc, a right-shifting-effect on the extraction curve of manganese and no effect on the extraction of cobalt. The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2014