Removable thermoplastic appliances modified by incisal cuts show altered biomechanical properties during tipping of a maxillary central incisor
نویسندگان
چکیده
BACKGROUND The present study aimed to evaluate the force delivery of removable thermoplastic appliances (RTAs), modified by different sized incisal cuts, during tipping of a maxillary central incisor in palatal and vestibular direction. METHODS Forty-five RTAs from three different materials (Biolon®, Erkodur®, Ideal Clear®) of the same thickness (1 mm) were used. Analysis was performed on a separated maxillary central incisor which was part of a resin model with a complete dentition. In 15 RTAs, of different material, a cut was inserted at the incisal edge of tooth 11. In 15 other appliances, the cut was extended to teeth 12 and 21. Fifteen aligners remained uncut. The experimental tooth was tipped starting from the zero position in 0.05° steps to a maximal deflection of ± 0.42° of the incisal edge in vestibular and palatal direction, after positioning the RTA onto the model. RESULTS The horizontal (Fx) and the vertical (Fz) force components were decreased by approximately half with increasing cut size. Fz values changed during palatal tipping from a weak intrusive force, for aligners without cut, to an extrusive force with increasing cut size. Compared to both other materials used (Erkodur® and Ideal Clear®), the Biolon® aligners showed significantly higher Fx and Fz values (p < 0.0001, respectively). CONCLUSIONS RTAs modified by different sized incisal cuts show altered biomechanical properties and an inversion of the vertical force component, during tipping of a maxillary central incisor.
منابع مشابه
High Force Levels Can Be Delivered With Thermoplastic Aligners Initial Forces Generated by Three Types of Thermoplastic Appliances on an Upper Central Incisor During Tipping
Background: Treatment of minor malocclusions with clear thermoplastic aligners is more commonly being used as an aesthetic alternative to fixed appliances. This can be done by manually resetting teeth on a plaster model or by models generated from a 3D computer model (Invisalign®). However, little research has been performed on the complex force systems generated by these types of appliances. O...
متن کاملThe orthodontic center of rotation of the maxillary central incisor.
The cephalometric records of sixty-four Class II, Division 1 cases treated exclusively with removable orthodontic appliances have been used in a study of the manner in which maxillary central incisors tilt. The center of rotation was most frequently located in the middle third of the incisor root. The longer the time interval between the pre- and posttreatment cephalograms, the more apical was ...
متن کاملCorrection of sever rotation of central maxillary incisor with fixed-removable appliance in the mixed dentition stage: A case report
BACKGROUND AND AIM: The aim of this case report is to present an approach used to correct severe rotation of anterior maxillary teeth in a pre-adolescent boy.CASE REPORT: The patient was an 8-year-old boy in the mixed dentition stage and severe rotation of upper right central incisor. Whip appliance was consisted of a removable plate, a cantilever spring and a bonded molar tube on rotated tooth...
متن کاملInfluence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping.
INTRODUCTION The aim of the study was to quantify the forces delivered by thermoplastic appliances made of 2 materials with 2 thicknesses to a maxillary central incisor during tipping. METHODS Two materials were tested, each in 2 thicknesses: Erkodur (Erkodent Erich Kopp GmbH, Pfalzgrafenweiler, Germany) 1.0 and 0.8 mm, and Biolon (Dreve Dentamid GmbH, Unna, Germany), 1.0 and 0.75 mm. For eac...
متن کاملInitial forces generated by three types of thermoplastic appliances on an upper central incisor during tipping.
The force properties of thermoformed appliances have not been systematically investigated. Therefore, the aim of the present study was to quantify the forces delivered by thermoplastic appliances manufactured from three different materials, with the same thickness, on a central upper incisor, during tipping. Five identical appliances were manufactured from three different materials all with a t...
متن کامل