Operational lessons drawn from pilot implementation of Xpert MTB/Rif in Brazil.
نویسندگان
چکیده
PROBLEM The World Health Organization has endorsed the Xpert MTB/RIF (Xpert), an automated polymerase-chain-reaction-based assay, for the rapid diagnosis of tuberculosis. However, large-scale use of a new technology calls for preparation and adaptation. APPROACH A pilot implementation study was conducted in two Brazilian cities to explore the replacement of sputum smear microscopy with Xpert. The laboratories included covered 70% of the tuberculosis cases diagnosed, had no overlap in population catchment areas, handled different workloads and were randomly shifted to Xpert. Sputum samples were collected through the same routine procedures. Before the study the medical information system was prepared for the recording of Xpert results. Laboratory technicians were trained to operate Xpert machines and health workers were taught how to interpret the results. LOCAL SETTING The average annual tuberculosis incidence in Brazil is around 90 cases per 100,000 population. However, co-infection with the human immunodeficiency virus and multidrug resistance are relatively infrequent (10% and < 2%, respectively). RELEVANT CHANGES Of the tested sputum samples, 7.3% were too scanty for Xpert and had to be examined microscopically. Ten per cent of Xpert equipment needed replacement, but spare parts were not readily available in the country. Absence of patient identification numbers led to the introduction of errors in the medical information system. LESSONS LEARNT For nationwide scale-up, a local service provider is needed to maintain the Xpert system. Ensuring cartridge availability is also essential. The capacity to perform smear microscopy should be retained. The medical information system needs updating to allow efficient use of Xpert.
منابع مشابه
Implementation of the Xpert MTB/RIF assay for tuberculosis in Mongolia: a qualitative exploration of barriers and enablers
OBJECTIVE The aim of our study was to identify barriers and enablers to implementation of the Xpert MTB/RIF test within Mongolia's National Tuberculosis Program. METHODS Twenty-foursemi-structured interviews were conducted between June and September 2015 with laboratory staff and tuberculosis physicians in Mongolia's capital Ulaanbaatar and regional towns where Xpert MTB/RIF testing had been ...
متن کاملImpact of introduction of Xpert MTB/RIF test on tuberculosis (TB) diagnosis in a city with high TB incidence in Brazil
BACKGROUND Xpert MTB/RIF is increasingly used in many countries as the initial diagnostic test for tuberculosis (TB). Few studies have evaluated the effect of Xpert on TB diagnosis under programmatic conditions in Brazil. The aim of the present study was to evaluate the impact of introduction of Xpert MTB/RIF on TB diagnosis in a city with high TB incidence in Brazil. METHODS We included pati...
متن کاملImplementing the Xpert® MTB/RIF Diagnostic Test for Tuberculosis and Rifampicin Resistance: Outcomes and Lessons Learned in 18 Countries
BACKGROUND The Xpert® MTB/RIF (Xpert) is an automated molecular test for simultaneous detection of tuberculosis (TB) and rifampicin resistance, recommended by the World Health Organization as the preferred diagnostic method for individuals presumed to have multi-drug resistant TB (MDR-TB) or HIV-associated TB. We describe the performance of Xpert and key lessons learned during two years of impl...
متن کاملAccuracy of different Xpert MTB/Rif implementation strategies in programmatic settings at the regional referral hospitals in Uganda: Evidence for country wide roll out
BACKGROUND Xpert MTB/RIF assay is a highly sensitive test for TB diagnosis, but still costly to most low-income countries. Several implementation strategies instead of frontline have been suggested; however with scarce data. We assessed accuracy of different Xpert MTB/RIF implementation strategies to inform national roll-out. METHODS This was a cross-sectional study of 1,924 adult presumptive...
متن کاملCorrection: Impact of Replacing Smear Microscopy with Xpert MTB/RIF for Diagnosing Tuberculosis in Brazil: A Stepped-Wedge Cluster-Randomized Trial
BACKGROUND Abundant evidence on Xpert MTB/RIF accuracy for diagnosing tuberculosis (TB) and rifampicin resistance has been produced, yet there are few data on the population benefit of its programmatic use. We assessed whether the implementation of Xpert MTB/RIF in routine conditions would (1) increase the notification rate of laboratory-confirmed pulmonary TB to the national notification syste...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bulletin of the World Health Organization
دوره 92 8 شماره
صفحات -
تاریخ انتشار 2014