Factors affecting real-time, cross-sectional echocardiographic imaging of perimembranous ventricular septal defects.
نویسندگان
چکیده
Recent studies suggest good prospective accuracy for two-dimensional echocardiographic imaging of ventricular septal defects (VSD). We obtained two-dimensional images with high-frequency, high-resolution scanners from 36 patients proved by cardiac catheterization to have perimembranous VSD. In 20 patients, the VSD was an isolated lesion and in 16 it was associated with other forms of heart disease. VSDs were imaged in long-axis, apical four-chamber and subcostal echocardiographic views. The smallest VSD imaged was 2 mm in diameter on echo; the largest, 23 mm. The imaged size of VSDs was larger at end-diastole than at end-systole by paired t test on all views (all p less than 0.005). VSD size also varied between views, with no predictive relationship except between apical and subcostal four-chamber views in diastole (r = 0.71, p less than 0.005). This agreed with qualitative direct observations of an ellipsoid or irregularly shaped VSD in operated patients. Echocardiographically measured VSD size normalized for either aortic root size or for patient weight could be used to separate isolated VSDs with large shunts (Qp/Qs greater than 2:1) from those with small shunts. Review of 250 two-dimensional echocardiographic studies from patients proved not to have a VSD revealed 28 planes of imaging with false-positive VSD. None of the false-positive VSDs was imaged consistently on all views. Additionally, a "T" artifact (broadening of septal edges around a VSD) has been found to be a reliable marker of true VSD imaging. To best quantify VSD size and to avoid false-positive diagnoses, it is necessary to use multiple views and to consider the marked changes in VSD size that occur between diastole and systole.
منابع مشابه
An echocardiographic study of perimembranous ventricular septal defect with left ventricular to right atrial shunting.
Twenty nine patients with isolated perimembranous ventricular septal defects were investigated by M mode, cross sectional, and pulsed Doppler echocardiography. Tricuspid valve anomalies were present in all six patients with a left ventricular-right atrial shunt but in only six (26%) of 23 patients who had interventricular shunts only. Systolic flutter of the tricuspid valve was shown in five (8...
متن کاملCross - sectional echocardiographic assessment of conditions with atrioventricular valve leaflets attached to the atrial septum at the same level JEFFREY
Ninety two patients with both atrioventricular valves attached to the atrial septum, roofing a perimembranous inlet ventricular septal defect, were assessed by cross-sectional echocardiography. In the group, 42 had an isolated perimembranous inlet ventricular septal defect, 31 had atrioventricular discordance, nine an atrioventricular septal defect with intact interatrial septum, and 10 a strad...
متن کاملLocalisation of ventricular septal defects by simultaneous display of superimposed colour Doppler and cross sectional echocardiographic images.
Precise non-invasive localisation of the site of a small ventricular septal defect was attempted using a new technique that simultaneously combines conventional cross sectional echocardiography with a Doppler system by superimposing the colour coded direction and velocity of blood flow directly on to real time ultrasound images. Twenty three patients with unoperated ventricular septal defects a...
متن کاملTransthoracic echocardiographic guidance of minimally invasive perventricular device closure of perimembranous ventricular septal defect without cardiopulmonary bypass: initial experience.
BACKGROUND Our purpose was to investigate the feasibility of transthoracic echocardiographic (TTE) guidance for minimally invasive periventricular device closure of perimembranous ventricular septal defects (VSDs). METHODS From June 2011 to September 2011, we enrolled 18 young children with perimembranous VSDs to receive minimally invasive device closure in our hospital. All of the patients w...
متن کاملCross-sectional echocardiographic assessment of conditions with atrioventricular valve leaflets attached to the atrial septum at the same level.
Ninety two patients with both atrioventricular valves attached to the atrial septum, roofing a perimembranous inlet ventricular septal defect, were assessed by cross-sectional echocardiography. In the group, 42 had an isolated perimembranous inlet ventricular septal defect, 31 had atrioventricular discordance, nine an atrioventricular septal defect with intact interatrial septum, and 10 a strad...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 63 3 شماره
صفحات -
تاریخ انتشار 1981