Beyond 40 MHz frontier: the future technologies for calibration and sensing of acoustic fields
نویسندگان
چکیده
Several techniques that are suitable for calibration of ultrasound hydrophones in the frequency range beyond 20 MHz are briefly reviewed. Attention is largely focused on substitution techniques because in contrast to the primary methods they are not as laborious and can be carried out relatively quickly. The techniques discussed include two acoustic procedures using swept frequency systems, an approach based on nonlinear propagation of acoustic waves in water medium, an acousto-optic technique that employs fiber optic sensors and a novel technique that is based on Time Reversed Acoustic (TRA) approach. It is shown that these techniques are capable of extending the frequency range in which the hydrophones can be calibrated up to 100 MHz. The importance of spatial averaging correction and its impact on the acoustic output measurements is also pointed out.
منابع مشابه
TiO2 based surface acoustic wave gas sensor with modified electrode dimensions for enhanced H2 sensing application
The design and optimization of nanostructure-based surface acoustic wave (SAW) gas sensor is analyzed based on TiO2 sensing layer and modified electrode dimensions. The sensitivity of the gas sensor depends upon the type of sensing layer used and active surface area obtained by varying the aspect ratio. The performance of the sensor is observed from 0.1ppm to 100ppm concentration of ...
متن کاملEvaluating the Effects of Dual Frequency Sonication Parameters on Acoustic Cavitation by Chemical Dosimeter Using Iodide
Background and Aims: Production of acoustic cavitation by sonication has been recently recommended as a targeted treatment. The experimental results from studies indicate that the activity of cavitation generated by bi- or multi-frequency ultrasound irradiation is higher than that caused by single frequency irradiation. In this study, effects dual (1 MHz and 40 kHz) and single frequency soni...
متن کاملDevelopment of calibration techniques for ultrasonic hydrophone probes in the frequency range from 1 to 100 MHz.
The primary objective of this work was to develop and optimize the calibration techniques for ultrasonic hydrophone probes used in acoustic field measurements up to 100 MHz. A dependable, 100 MHz calibration method was necessary to examine the behavior of a sub-millimeter spatial resolution fiber optic (FO) sensor and assess the need for such a sensor as an alternative tool for high frequency c...
متن کاملطول میرایی امواج مغناطوآکوستیک آرام مشاهده شده در حلقههای تاج با استفاده ازتلسکوپ اس- دی- او
Slow magneto-acoustic waves are often observed in polar plumes and active region fan loops. The observed periodicities of these waves are in the range of 1- 40 minutes. Mainly, the ratio of damping time to the oscillation period is less than 2 (equal to the ratio damping length to the wave length), which corresponds to the strong damping regime. In general, slow magneto-acoustic waves can be da...
متن کاملEstimation of Actual Evapotranspiration, Water productivity, and Irrigation Efficiency of Wheat Fields in Surface and Sprinkler Irrigation Systems Using Remote Sensing
In arid and semi-arid regions, water resource management and optimization of applying irrigation water are particularly important. For optimization of applying irrigation water, the estimated values of actual evapotranspiration are necessary for avoiding excessive or inadequate applying water. The estimation of actual crop evapotranspiration is not possible in large areas using the traditional ...
متن کامل