Bias and Self-Bias of Magnetic Macroparticle Filters for Cathodic Arc Plasmas

نویسندگان

  • Eungsun Byon
  • André Anders
چکیده

Curved magnetic filters are often used for the removal of macroparticles from cathodic arc plasmas. This study addresses the need to further reduce losses and improving plasma throughput. The central figure of merit is the system coefficient, κ , defined as filtered ion current normalized by the plasma-producing arc current. The coefficient κ is investigated as a function of continuous and pulsed magnetic field operation, magnetic field strength, external electric bias, and arc amplitude. It increases with positive filter bias but saturates at about 15 V for relatively low magnetic field (~10 mT), whereas stronger magnetic fields lead to higher κ with saturation at about 25 V. Further increase of positive bias reduces κ . These findings are true for both pulsed and continuous filters. Bias of pulsed filters has been realized using the voltage drop across a self-bias resistor, eliminating the need for a separate bias circuit. Almost 100 A of filtered copper ions have been obtained in pulsed mode, corresponding to 0.04 κ ≈ . The results are interpreted by a simplified potential trough model.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging the separation of cathodic arc plasma and macroparticles in curved magnetic filters

Cathodic vacuum arc plasmas can be used to produce well adherent, dense, highquality films and coatings provided macroparticles are removed from the plasma. Both plasma and macroparticles are produced at cathode spots, and in most cases both can easily be observed because they emit light. The nature of this light emission is briefly discussed. Using open, curved solenoids as magnetic filters, o...

متن کامل

Macroparticles in films deposited by steered cathodic arc

The macroparticle content of titanium films deposited using a steered vacuum cathodic arc has been investigated. It has been found that the macroparticle number decreases with increasing steering magnetic field strength, and experimental results are found to be consistent with the model in which the number and mass of macroparticles arising from a cathode spot are proportional to the cathode sp...

متن کامل

Observation of Self-Sputtering in Energetic Condensation of Metal Ions

The condensation of energetic metal ions on a surface may cause self-sputtering even in the absence of substrate bias. Charge-stateaveraged self-sputtering yields were determined for both zirconium and gold ions generated by a cathodic vacuum arc. Films were deposited on differently biased substrates exposed to streaming Zr and Au vacuum arc plasma. The self-sputtering yields for both metals we...

متن کامل

Die Materials Modulated Pulsed Power Magnetron Sputtering for Die Surface Engineering

The utility of hard tribological coatings based on transition nitrides (e.g. CrN, TiAlN, CrAlN, etc.) as protective layers on various forming tools (e.g. die and its components used in high pressure die casting) has led to improvements in increased die life, reduced machine down time, and improved product quality. Moreover, recent advances in the coating design made it possible to obtain nanosc...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003