Bravo 48-hour Wireless pH Monitoring in Patients With Non-cardiac Chest Pain. Objective Gastroesophageal Reflux Disease Parameters Predict the Responses to Proton Pump Inhibitors

نویسندگان

  • Georgios Karamanolis
  • Konstantinos Triantafyllou
  • Panagiota Psatha
  • Ioannis Vlachogiannakos
  • Asimina Gaglia
  • Dimitrios Polymeros
  • Smaragdi Fessatou
  • Maria Triantafyllou
  • Ioannis S Papanikolaou
  • Spiros D Ladas
چکیده

BACKGROUND/AIMS In patients with non-cardiac chest pain (NCCP), gastroesophageal reflux disease (GERD) is the commonest cause and ambulatory pH is of great value in identifying these patients. However, parameters in the context of predicting therapeutic response are still unknown. By extending the monitoring period, we could better evaluate the best evidence for GERD association. Our aims were (1) to compare the outcomes of 48-hour pH monitoring to 24-hour and (2) to determine whether objective parameters could predict the treatment success in patients with NCCP using Bravo pH system. METHODS Pathological esophageal acid reflux (PEAR) and positive symptom index (SI) were calculated after 24-hour and compared to the 48-hour study. Evidence suggestive of GERD diagnosis was considered if PEAR and/or SI (+) were present on each different day. After pH study, all patients received proton pump inhibitor twice a day for 4 weeks. Treatment success was determined at the end of therapy. RESULTS Thirty-two patients with NCCP participated. GERD was identified in 20 (62.5%) patients; 17 (53.1%) had PEAR, 3 (9.4%) SI (+) and 7 (22%) both. Twelve (41%) patients exhibited PEAR values on day 1, while 17 after 2 days; a 12.1% gain. SI (+) was found in 6 patients (18.8%) on day 1 and in 4 more on day 2, a gain of 12.5%. Significantly higher proportion of patients with GERD indicators showed improvement compared to those without (90% vs 16.7%, P < 0.005). CONCLUSIONS In patients with NCCP, 48-hour pH measurement identified GERD as the cause of NCCP with an increased yield by almost 12% compared to 12 hours. Objective GERD parameters could predict response to antireflux therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is Wireless Capsule pH Monitoring Better Than Catheter Systems?

CC This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons. org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. *Correspondence: Joon Seong Lee, MD, PhD Institute for Digestive Research, Department of...

متن کامل

Gastroesophageal reflux disease-related symptom recurrence in patients discontinuing proton pump inhibitors for Bravo® wireless esophageal pH monitoring study.

BACKGROUND Patients with gastroesophageal reflux disease (GERD) are treated with proton pump inhibitors (PPIs). Those that do not achieve symptom relief, or non-responders, usually undergo esophageal pH monitoring off PPIs in order to confirm the presence of GERD. AIMS To assess the efficacy of the reverse-PPI trial in evaluating the presence of GERD or its recurrence rates, as well as to ide...

متن کامل

Clinical value of wireless pH-monitoring of gastro-esophageal reflux in children before and after proton pump inhibitors

BACKGROUND Wireless pH-monitoring is an accurate method for diagnosing adults with gastroesophageal reflux disease (GERD). The aim of this study was to evaluate the use of the Bravo capsule on children investigated for GERD in terms of safety, tolerability and feasibility before and after administration of proton pump inhibitors. METHODS A Bravo capsule was inserted during upper endoscopy und...

متن کامل

Inconsistency in the Diagnosis of Functional Heartburn: Usefulness of Prolonged Wireless pH Monitoring in Patients With Proton Pump Inhibitor Refractory Gastroesophageal Reflux Disease

BACKGROUND/AIMS The diagnosis of functional heartburn is important for management, however it stands on fragile pH monitoring variables, ie, acid exposure time varies from day to day and symptoms are often few or absent. Aim of this study was to investigate consistency of the diagnosis of functional heartburn in subsequent days using prolonged wireless pH monitoring and its impact on patients' ...

متن کامل

GERD assessment including pH metry predicts a high response rate to PPI standard therapy

BACKGROUND Inadequate response to proton pump inhibitor (PPI) therapy in patients with gastroesophageal reflux disease (GERD) is reported in up to 40%. Patients with non erosive reflux disease (NERD) have lower response rates compared to patients with erosive reflux disease (ERD); pH metry contributes to GERD diagnosis and is critical for proper diagnosis of NERD. Aim of the study was to assess...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -