Wireless Stand-alone Portable Patient Monitoring and Logging System

نویسندگان

  • Taha Landolsi
  • Abdul-Rahman Al-Ali
  • Yousef Al-Assaf
چکیده

1 Based on “Portable Integrated Multi-Signal Patient Monitoring System ", by M. El Korek, R. Aloul, T. Landolsi, A.R. Al-Ali, and Y. Al-Assaf which appeared in the 3rd International Conference on Innovations in Information Technology (IIT06). © [2006] IEEE. Abstract—In this paper, we propose a wireless stand-alone, embedded system design that integrates the monitoring of three biomedical parameters into a single personal medical device. The three parameters are: blood glucose level, heart rate, and pulse oximetry. The goal of this work is to build a compact and cost-effective device capable of monitoring several medical parameters while patients conduct their normal daily activities, and store these parameter readings in an embedded system-based portable device. A communication protocol and patient monitoring software application are developed to store data that can be later downloaded to a physician’s workstation for analysis and diagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Health Monitoring and Logging System for Patients using Wireless Standalone Network

Telemedicine (health-care delivery where physicians examine distant patients using mobile communications technologies) has been heralded as one of several possible solutions to some of the medical dilemmas that face many developing countries. In this paper, we propose a wireless stand-alone novel approach to patient health monitoring. The embedded system designed integrates the monitoring of th...

متن کامل

Remote Data Acquisition of Physical Parameters Using Master-Slave Utility of Microcontroller

Improve the performance of remotely situated device control and data monitoring, acquisition with parameter such as temperature, pressure, vibration, humidity on real time basis give the data modularity as well as low data processing time. The infrastructure of the existing RF network is used, which is based on supervisory control, monitoring and data acquisition demands constant development an...

متن کامل

Description of a Portable Wireless Device for High-Frequency Body Temperature Acquisition and Analysis

We describe a device for dual channel body temperature monitoring. The device can operate as a real time monitor or as a data logger, and has Bluetooth capabilities to enable for wireless data download to the computer used for data analysis. The proposed device is capable of sampling temperature at a rate of 1 sample per minute with a resolution of 0.01 °C . The internal memory allows for stand...

متن کامل

Development of system decision support tools for behavioral trends monitoring of machinery maintenance in a competitive environment

The article is centred on software system development for manufacturing company that produces polyethylene bags using mostly conventional machines in a competitive world where each business enterprise desires to stand tall. This is meant to assist in gaining market shares, taking maintenance and production decisions by the dynamism and flexibilities embedded in the package as customers’ demand ...

متن کامل

A Group Monitoring Wireless System for Health Care Monitoring

Body Area Network (BAN) is a sensor network technology for monitoring and logging vital signs of a person, such as cardiac frequency and blood pressure. The main goal of BAN is to make remote monitoring possible. In this paper a group monitoring approach is presented. The work differs from others because the idea is to monitor a group of patients in a hospital or clinic at the same time while h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JCM

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2007