Myocardial first pass perfusion: steady-state free precession versus spoiled gradient echo and segmented echo planar imaging.
نویسندگان
چکیده
The imaging sequences used in first pass (FP) perfusion to date have important limitations in contrast-to-noise ratio (CNR), temporal and spatial resolution, and myocardial coverage. As a result, controversy exists about optimal imaging strategies for FP myocardial perfusion. Since imaging performance varies from subject to subject, it is difficult to form conclusions without direct comparison of different sequences in the same subject. The purpose of this study was to directly compare the saturation recovery SSFP technique to other more commonly used myocardial first pass perfusion techniques, namely spoiled GRE and segmented EPI. Differences in signal-to-noise ratio (SNR), CNR, relative maximal upslope (RMU) of signal amplitude, and artifacts at comparable temporal and spatial resolution among the three sequences were investigated in computer simulation, contrast agent doped phantoms, and 16 volunteers. The results demonstrate that SSFP perfusion images exhibit an improvement of approximately 77% in SNR and 23% in CNR over spoiled GRE and 85% SNR and 50% CNR over segmented EPI. Mean RMU was similar between SSFP and spoiled GRE, but there was a 58% increase in RMU with SSFP versus segmented EPI.
منابع مشابه
Spoiled & Balanced Gradient Echo Methods
Imaging with spoiled, balanced or nonbalanced gradient echo (GRE) refers to a class of fast imaging sequences that use a dynamic equilibrium or steady state signal for imaging. As originally introduced in 1958 by Carr (1) for NMR spectroscopy, a dynamic equilibrium or steadystate can be established by a train of radio-frequency (RF) excitation pulses interleaved by periods of ‘free precession’,...
متن کاملFree-breathing myocardial T1 mapping using magnetization-prepared slice interleaved spoiled gradient echo imaging
Background Quantitative myocardial T1 mapping and extracellular volume fraction (ECV) show promise for non-invasive assessment of cardiomyopathies. Most available T1 mapping sequences use a single slice breath-hold acquisition with balanced steady state free precession (b-SSFP) readout [1]. However, b-SSFP readout is sensitive to B0 field inhomogeneity and is potentially T2 dependent [1]. In th...
متن کاملDirect comparison of myocardial perfusion cardiovascular magnetic resonance sequences with parallel acquisition.
PURPOSE To directly compare the three main myocardial perfusion cardiovascular magnetic resonance (CMR) sequences incorporating parallel acquisition methods. MATERIALS AND METHODS In 15 subjects (12 men, 57 +/- 15.7 years) referred for diagnostic coronary angiography, we acquired first-pass perfusion images (0.1 mmol/kg gadolinium-DTPA) at rest and during adenosine (140 microg/kg/min) on thre...
متن کاملFeasibility and preliminary diagnostic results of pixel-wise quantification of regadenoson first pass cardiac magnetic resonance perfusion imaging
Methods Forty-seven patients had 1.5T steady state free precession, regadenoson stress perfusion CMR and either a ≤ 30% coronary narrowing by CT angiography (CTA) or a ≥70% stenosis by invasive coronary angiography (ICA). CMR perfusion pixel maps were generated by a modelconstrained deconvolution with and without the myocardial segmentation. The two independent observers were blinded to clinica...
متن کاملQuantitative Myocardial Perfusion Using Conventional Single-Bolus Contrast Imaging Overestimates Absolute Myocardial Blood Flow Compared with Dual-Bolus or Dual-Sequence Cardiac MR Methods
Introduction: Estimates of myocardial blood flow (MBF) from first-pass contrast-enhanced cardiac magnetic resonance (CMR) imaging require accurate measurement of the arterial input function (AIF) from the left-ventricular (LV) blood pool. Both dual-bolus [1] and dual-sequence [2,3] CMR methods have been proposed to maintain the linearity of the LV signal during the contrast passage. Several stu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 54 5 شماره
صفحات -
تاریخ انتشار 2005