Surface EMG force modeling with joint angle based calibration.

نویسندگان

  • Javad Hashemi
  • Evelyn Morin
  • Parvin Mousavi
  • Keyvan Hashtrudi-Zaad
چکیده

In this paper, a calibration method to compensate for changes in SEMG amplitude with joint angle is introduced. Calibration factors were derived from constant amplitude surface electromyogram (SEMG) recordings from the biceps brachii (during elbow flexion) and the triceps brachii (during elbow extension) across seven elbow joint angles. SEMG data were then recorded from the elbow flexors (biceps brachii and brachioradialis) and extensors (triceps brachii) during isometric, constant force flexion and extension contractions at the same joint angles. The resulting force at the wrist was measured. The fast orthogonal search method was used to find a mapping between the system inputs - estimated SEMG amplitudes and joint angle - and the system output - measured force, for both calibrated and non-calibrated SEMG data. Models developed with calibrated data yielded a statistically significant improvement in force estimation compared to models developed with non-calibrated data, suggesting that the calibration method can compensate for changes in the SEMG-force relationship with changing joint angle. It was also found that the number of non-linear, joint angle-dependent terms used in the SEMG-force model was reduced with calibration. Additionally, initial inter-session analysis performed for four subjects suggests that calibration values can be used for subsequent recording sessions, and different output force levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of Upper Limb Joint Angle Using Surface EMG Signal

In the development of robot-assisted rehabilitation systems for upper limb rehabilitation therapy, human electromyogram (EMG) is widely used due to its ability to detect the user intended motion. EMG is one kind of biological signal that can be recorded to evaluate the performance of skeletal muscles by means of a sensor electrode. Based on recorded EMG signals, user intended motion could be ex...

متن کامل

Neuromuscular adaptations associated with knee joint angle-specific force change.

PURPOSE Neuromuscular adaptations to joint angle-specific force increases after isometric training have not yet been fully elucidated. This study examined angle-specific neuromuscular adaptations in response to isometric knee extension training at short (SL, joint angle 38.1° ± 3.7°) versus long (LL, 87.5° ± 6.0°) muscle lengths. METHODS Sixteen men trained three times a week for 6 wk either ...

متن کامل

A System for the Synchronized Recording of Sonomyography, Electromyography and Joint Angle

Ultrasound and electromyography (EMG) are two of the most commonly used diagnostic tools for the assessment of muscles. Recently, many studies reported the simultaneous collection of EMG signals and ultrasound images, which were normally amplified and digitized by different devices. However, there is lack of a systematic method to synchronize them and no study has reported the effects of ultras...

متن کامل

EMG-Driven Forward-Dynamic Estimation of Muscle Force and Joint Moment about Multiple Degrees of Freedom in the Human Lower Extremity

This work examined if currently available electromyography (EMG) driven models, that are calibrated to satisfy joint moments about one single degree of freedom (DOF), could provide the same musculotendon unit (MTU) force solution, when driven by the same input data, but calibrated about a different DOF. We then developed a novel and comprehensive EMG-driven model of the human lower extremity th...

متن کامل

Influence of joint angle on EMG-torque model during constant-posture, quasi-constant-torque contractions.

Electromyogram (EMG)-torque modeling is of value to many different application areas, including ergonomics, clinical biomechanics and prosthesis control. One important aspect of EMG-torque modeling is the ability to account for the joint angle influence. This manuscript describes an experimental study which relates the biceps/triceps surface EMG of 12 subjects to elbow torque at seven joint ang...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology

دوره 23 2  شماره 

صفحات  -

تاریخ انتشار 2013