Evaluation of LV diastolic function from color M-mode echocardiography.
نویسندگان
چکیده
OBJECTIVES this study evaluated early diastolic filling dynamics using a semiautomated objective analysis of filling velocities obtained from color M-mode echocardiography. BACKGROUND diastolic function can be evaluated from color M-mode echocardiography by measuring the early diastolic flow propagation velocity (Vp) from the slope of a single linear approximation of an isovelocity contour. However, this method has limitations and may not accurately represent diastolic filling. METHODS we used a semiautomated objective analysis of color M-mode echocardiograms from a development cohort of 125 patients with varying diastolic function to quantify left ventricular filling velocities. Early diastolic filling was not accurately described with a single propagation velocity; instead, the rapid initial filling velocity abruptly decelerated to a slower terminal velocity. Then, we evaluated a new measure of diastolic function in a separate group of 160 patients. RESULTS compared with normal filling, diastolic dysfunction with restricted filling had a lower initial velocity (53 ± 21 cm/s vs. 87 ± 29 cm/s, p < 0.001), and the deceleration point occurred closer to the mitral annulus (2.4 ± 0.6 cm vs. 3.1 ± 0.7 cm, p < 0.05). The product of the initial velocity and the distance to the deceleration point from the mitral annulus, indicating the strength of the early filling (Vs), was progressively reduced with diastolic dysfunction. In a separate validation cohort of 160 patients, Vs better recognized diastolic dysfunction (classified by reduced diastolic intraventricular pressure gradient, elevated pulmonary capillary wedge pressure, or elevated B-type natriuretic peptide) than Vp did. CONCLUSIONS early diastolic flow propagation occurs with an initial rapid velocity that abruptly decelerates to a terminal velocity. With diastolic dysfunction, the initial velocity is slower and the deceleration point occurs closer to the mitral annulus than with normal filling. A new parameter that combines these 2 effects (Vs) provides a more accurate assessment of diastolic function than the conventional propagation velocity.
منابع مشابه
Left ventricular inflow propagation velocity for diastolic function testing: head-to-head comparison between velocity-encoded MRI and color M-mode Doppler echocardiography
Background The inflow propagation velocity (Vprop) of the early filling wave has been proposed as an accurate marker of left ventricular (LV) diastolic function [1]. Traditionally, Color M-mode echo Doppler is used for Vprop-assessment. However, this method has not been validated against an alternative modality such as velocity-encoded (VE) MRI for assessing Vprop. The purpose of this study was...
متن کاملCardiac Function and Aortic Valve Intervention - Echocardiographic Studies of Myocardial Recovery in Patients with Severe Aortic Valve Disease
....................................................................................................... 1 POPULÄRVETENSKAPLIG SAMMANFATTNING ................................. 3 LIST OF ORIGINAL PAPERS ........................................................................ 5 ABBREVIATIONS ............................................................................................. 6 INTRODUCTIO...
متن کاملUse of color kinesis for evaluation of left ventricular filling in patients with dilated cardiomyopathy and mitral regurgitation.
OBJECTIVES We tested the feasibility of using analysis of color kinesis images to objectively assess global and regional left ventricular (LV) diastolic function in patients with dilated cardiomyopathy (DCM). In addition, the ability of this technique to track drug-induced changes on LV diastolic properties was studied. BACKGROUND Diastolic dysfunction contributes to symptomatology in patient...
متن کاملWhat parameters affect left ventricular diastolic flow propagation velocity? in vitro studies using color m-mode doppler echocardiography
BACKGROUND Insufficient data describe the relationship of hemodynamic parameters to left ventricular (LV) diastolic flow propagation velocity (Vp) measured using color M-mode Doppler echocardiography. METHODS An in vitro LV model used to simulate LV diastolic inflow with Vp measured under conditions of varying: 1) Stroke volume, 2) heart rate (HR), 3) LV volume, 4) LV compliance, and 5) trans...
متن کاملEvaluation of left ventricular diastolic function with a dedicated cadmium-zinc-telluride cardiac camera: comparison with Doppler echocardiography.
AIMS To evaluate the relationships between measures of left ventricular (LV) filling dynamics at cadmium-zinc-telluride (CZT) imaging and indexes of LV diastolic function at transthoracic echocardiography. METHODS AND RESULTS Two hundred and forty-seven patients underwent myocardial perfusion imaging at rest and after stress with a low-dose CZT protocol and a baseline transthoracic echocardio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JACC. Cardiovascular imaging
دوره 4 1 شماره
صفحات -
تاریخ انتشار 2011