OBJECTIVE With the increasing number of patients undergoing positron emission tomography (PET) scans and the fact that multiple whole body acquisitions are performed during therapy monitoring, the reduction of scan time as well as of the injected radioactive dose are important issues. However, short scan time and reduction of the injected radiation dose result in low count statistics, which significantly affects the quality of the reconstructed images and accurate diagnosis. SUBJECTS AND METHODS The aim of this study was to explore the effect of low count statistics on ordered subset expectation maximization regularized with median root prior (OS-MRP-OSL) reconstructed images. By optimizing OS-MRP-OSL we determine whether a satisfactory handling of the noise properties and bias can be achieved compared to post-filtered ordered subset expectation maximization (OSEM), which will lead to improved image quality in simulations with more noise. We used realistic simulated PET data of a thorax with lesions corresponding to tumors with different intensities. RESULTS OS-MRP-OSL provided reduced noise from post-filtered OSEM, without having the negative effect of blurring. On the other hand, bias presented no significant difference. CONCLUSION This work is relevant to future PET reconstruction of clinical images and PET-magnetic resonance investigations where the reduced injected dose will allow imaging a larger cohort of humans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Quantitative evaluation of block-iterative reconstruction image in PET: comparison of the dynamic RAMLA algorithm and OSEM algorithm].

PURPOSE Iterative reconstruction has been successfully used in whole-body PET imaging because of reductions in noise and scanning time. However, there are plural algorithms for image reconstruction such as OSEM, RAMLA and Dynamic RAMLA. Dynamic RAMLA (DRAMA) is an iterative algorithm similar to RAMLA, but the relaxation parameter is controlled in such a way that the propagation of noise from pr...

متن کامل

Effects of regularisation priors on dynamic PET Data

Institute of Neuroscience and Medicine-4, Forschungszentrum Juelich, Germany Dynamic PET provides temporal information about tracer uptake. However, each PET frame has usually low statistics, resulting in noisy images. The goal is to study effects of prior regularisation on dynamic PET data. Quantification and noise in imagedomain and time-domain as well as impact on parametric images is assess...

متن کامل

Edge Artifacts in Point Spread Function-based PET Reconstruction in Relation to Object Size and Reconstruction Parameters

Objective(s): We evaluated edge artifacts in relation to phantom diameter and reconstruction parameters in point spread function (PSF)-based positron emission tomography (PET) image reconstruction.Methods: PET data were acquired from an original cone-shaped phantom filled with 18F solution (21.9 kBq/mL) for 10 min using a Biograph mCT scanner. The images were reconstructed using the baseline or...

متن کامل

Simulation-based evaluation of OSEM iterative reconstruction methods in dynamic brain PET studies

The reconstruction of dynamic PET data is usually performed using filtered backprojection algorithms (FBP). This method is fast, robust, linear and yields reliable quantitative results. However, the use of FBP for low count data, such as dynamic PET data, generally results in poor visual image quality, exhibiting high noise, disturbing streak artifacts and low contrast. These signal-to-noise ra...

متن کامل

Impact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer

Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hellenic journal of nuclear medicine

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 2015