Improving microbial air quality in air-conditioned mass transport buses by opening the bus exhaust ventilation fans.

نویسندگان

  • Pipat Luksamijarulkul
  • Nongphon Arunchai
  • Soavalug Luksamijarulkul
  • Orawan Kaewboonchoo
چکیده

The air quality in air-conditioned mass transport buses may affect bus drivers' health. In-bus air quality improvement with the voluntary participation of bus drivers by opening the exhaust ventilation fans in the bus was implemented in the Seventh Bus Zone of Bangkok Mass Transit Authority. Four bus numbers, including bus numbers 16, 63, 67 and 166, were randomly selected to investigate microbial air quality and to observe the effect of opening the exhaust ventilation fans in the bus. With each bus number, 9 to 10 air-conditioned buses (total, 39 air-conditioned buses) were included. In-bus air samples were collected at 5 points in each studied bus using the Millipore Air Tester. A total of 195 air samples were cultured for bacterial and fungal counts. The results reveal that the exhaust ventilation fans of 17 air-conditioned buses (43.6%) were opened to ventilate in-bus air during the cycle of the bus route. The means +/- SD of bacterial counts and fungal counts in the studied buses with opened exhaust ventilation fans (83.8 +/- 70.7 and 38.0 +/- 42.8 cfu/m3) were significantly lower than those in the studied buses without opened exhaust ventilation fans (199.6 +/- 138.8 and 294.1 +/- 178.7 cfu/m3), p < 0.0005. All the air samples collected from the studied buses with opened exhaust ventilation fans were at acceptable levels (< 500 cfu/m3) compared with 4.6% of the air samples collected from the studied buses without opened exhaust ventilation fans, which had high levels (> 500 cfu/m3). Of the studied buses with opened exhaust ventilation fans (17 buses), the bacterial and fungal counts after opening the exhaust ventilation fans (68.3 +/- 33.8 and 28.3 +/- 19.3 cfu/m3) were significantly lower than those before opening the exhaust ventilation fans (158.3 +/- 116.9 and 85.3 +/- 71.2 cfu/m3), p < 0.005.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of opening diffuser and return vent location on air quality, thermal comfort and energy saving in desk displacement ventilation (DDV) system

Many investigations have recently been performed on return vent height and indicate that having 1.3 m distance from the floor is the optimized height for it. In this article, the effect of distance between opening diffuser and return vent on air quality, thermal comfort and energy saving was investigated. According to the results, by increasing the distance between opening and return vent up to...

متن کامل

Study of In-Vehicle Pollutant Variation in Public Transport Buses Operat- ing on Alternative Fuels in the City of Toledo, Ohio

This study focuses on determining the variation of indoor pollutants in public transport buses in the City of Toledo running on biodiesel (BD) and ultra low sulfur diesel (ULSD). The indoor pollutants monitored are carbon dioxide (CO2), carbon monoxide (CO), sulfur dioxide (SO2), nitric oxide (NO), and particulate matter (PM). Temperature (Temp.) and relative humidity (RH) are also measured ins...

متن کامل

Recommended Ventilation Strategies for Energy-efficient Production Homes

This report evaluates residential ventilation systems for the U.S. Environmental Protection Agency's (EPA's) ENERGY STAR ® Homes program and recommends mechanical ventilation strategies for new, low-infiltration, energy-efficient, single-family, ENERGY STAR production (site-built tract) homes in four climates: cold, mixed (cold and hot), hot humid, and hot arid. Our group in the Energy Analysis...

متن کامل

Controlling Greenhouse Ventilation Inlets by Pressure Difference

Table 1. Standard air density as a function of elevation above sea level (at 70F and 50% relative humidity). M echanical ventilation can be divided into three types: negative-, positive-, and neutral-pressure ventilation. Negativepressure systems use fans to exhaust air, thereby creating a slight partial vacuum that draws fresh air in from outdoors. Negative-pressure ventilation systems are use...

متن کامل

Environmental impact assessment of bus rapid transit (BRT) in the Metropolitan City of Tehran

Bus rapid transit is an innovative, high capacity, lower cost public transit solution in metropolitan cities. Idea is to dedicate lanes for quick and efficient transport of passengers to their destinations. In the present investigation the environmental impact assessment of bus rapid transit  in Tehran metropolitan city is brought out. For this purpose bus rapid transit Lane No. 10 is investiga...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Southeast Asian journal of tropical medicine and public health

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2005