BACKGROUND Fluid energy loss across stenotic aortic valves is influenced by factors other than the valve effective orifice area (EOA). We propose a new index that will provide a more accurate estimate of this energy loss. METHODS AND RESULTS An experimental model was designed to measure EOA and energy loss in 2 fixed stenoses and 7 bioprosthetic valves for different flow rates and 2 different aortic sizes (25 and 38 mm). The results showed that the relationship between EOA and energy loss is influenced by both flow rate and aortic cross-sectional area (A(A)) and that the energy loss is systematically higher (15+/-2%) in the large aorta. The coefficient (EOAxA(A))/(A(A)-EOA) accurately predicted the energy loss in all situations (r(2)=0.98). This coefficient is more closely related to the increase in left ventricular workload than EOA. To account for varying flow rates, the coefficient was indexed for body surface area in a retrospective study of 138 patients with moderate or severe aortic stenosis. The energy loss index measured by Doppler echocardiography was superior to the EOA in predicting the end points, which were defined as death or aortic valve replacement. An energy loss index </=0.52 cm(2)/m(2) was the best predictor of adverse outcomes (positive predictive value of 67%). CONCLUSIONS This new energy loss index has the potential to reflect the severity of aortic stenosis better than EOA. Further prospective studies are necessary to establish the relevance of this index in terms of clinical outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy Loss Index in Aortic Stenosis

In the American Heart Association–American College of Cardiology and European Society of Cardiology–European Association for Cardio-Thoracic Surgery guidelines, aortic valve replacement (AVR) is considered a class I indication in patients with aortic stenosis (AS) if the stenosis is severe and the patient has symptoms or left ventricular ejection fraction <50%. Hence, accurate assessment of the...

متن کامل

Energy loss index in aortic stenosis: from fluid mechanics concept to clinical application.

aortic valve replacement (AVR) is considered a class I indication in patients with aortic stenosis (AS) if the stenosis is severe and the patient has symptoms or left ventricular ejection fraction <50%. Hence, accurate assessment of the hemodynamic severity of the valvular stenosis is crucial for clinical decision making. The stenosis severity is generally determined by measuring the transvalvu...

متن کامل

Assessment of energy loss in aortic stenosis using Bayesian multipoint phase-contrast MRI

Background Aortic stenosis is the most prevalent valvular heart disease. The current gold standard for determination of the disease severity is Doppler echocardiography, but the decision for valve replacement is mostly based on the patient experiencing symptoms [1]. Doppler echocardiography measures the velocity across the valve, which is only indirectly linked to the energy loss associated wit...

متن کامل

Turbulence mapping: a new CMR approach for assessment of aortic stenosis

Background Pressure loss estimation based on the simplified Bernoulli equation frequently misclassifies the severity of aortic stenosis. Consequently, several investigators have on the basis of fluid dynamics theory derived pressure loss indices aimed at improving the clinical approach to pressure estimation [1-3]. However, CMR may offer a stronger alternative. The primary cause of pressure los...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 101 7  شماره 

صفحات  -

تاریخ انتشار 2000