Comparison of electromyographic activity during eccentrically versus concentrically loaded isometric contractions.
نویسندگان
چکیده
Electromyographic (EMG) amplitude and mechanical tension are directly related during isometric contraction. Maximal voluntary isometric contractions are typically elicited through two different procedures; resisting a load, which is eccentric in nature, and contracting against an immovable object, which is concentric in nature. A wealth of literature exists indicating that EMG amplitude during concentric contractions is greater than that of eccentric contractions of the same magnitude. However, the effects of different methods to elicit isometric contraction on EMG amplitude have yet to be investigated. The purpose of this study was to compare EMG amplitudes under different loading configurations designed to elicit isometric muscle contraction. Twenty healthy volunteers (10 males and 10 females, age=23+/-2 yrs, height=1.7+/-0.09 m, mass=69.9+16.8 kg) performed a maximal voluntary plantarflexion effort for which the vertical ground reaction force (GRFv) sampled from a force plate and surface EMG of the soleus were recorded. Participants then performed isometric plantarflexion at 20%, 30%, 40%, and 50% GRFv(max) in a seated position, from a neutral ankle position, under two different counterbalanced isometric loading conditions (concentric and eccentric). For concentric loading conditions, the subject contracted against an immovable resistance to the specified %GRFv identified via visual and auditory feedback. For eccentric loading conditions, subjects contracted against an applied load placed on the distal anterior thigh that produced the specified %GRFv. This applied load had the tendency to force the ankle into dorsiflexion. Therefore, plantarflexion force, in an attempt to maintain the ankle in a neutral position, resisted lengthening of the plantarflexor musculature, thus representing eccentric loading during an isometric contraction. Mean EMG amplitude was compared across loading levels and types using a 2 (loading type: concentric, eccentric)x4 (loading level: 20%, 30%, 40%, 50% GRFv) repeated-measures ANOVA. The main effect for loading level was significant (p=0.007). However, the main effect for loading type, and the loading type x loading level interaction were non-significant (p>0.05). The present findings provide evidence that isometric muscle contractions loaded in either concentric or eccentric manners elicit similar EMG amplitudes, and are therefore comparable in research settings.
منابع مشابه
Pain and fatigue after concentric and eccentric muscle contractions.
1. Normal subjects performed a step test in which the quadriceps of one leg contracted concentrically while the contralateral muscle contracted eccentrically. 2. Maximal voluntary force and the force: frequency relationship were altered bilaterally as a result of the exercise, the changes being greater in the muscle which had contracted eccentrically. Recovery occurred over 24 h. 3. Electromyog...
متن کاملEccentric ergometry: increases in locomotor muscle size and strength at low training intensities.
Lengthening (eccentric) muscle contractions are characterized by several unusual properties that may result in unique skeletal muscle adaptations. In particular, high forces are produced with very little energy demand. Eccentrically trained muscles gain strength, but the specific nature of fiber size and composition is poorly known. This study assesses the structural and functional changes that...
متن کاملThe effects of kinetic energy on concentric and eccentric isokinetic work.
This investigation examined inertial effects on work output during isokinetic concentric knee extension and eccentric knee flexion. Total work (Wtotal) included work due to kinetic energy (Wkin), with respect to gravity (Wgrav), and against the dynamometer (Wdyn). Eighteen resistance-trained participants (9 males, 9 females) performed maximal voluntary concentric (90, 150, 210, 270 deg/s) and e...
متن کاملRelationship between muscle length, muscle activity, and torque of the hamstring muscles.
The relationship between muscle length, integrated electromyographic activity, and torque of the biceps femoris muscle was investigated while the line of action of the muscle at the knee was held constant. Muscle length was changed by varying the hip joint angle. Sixteen subjects produced 1) maximal isometric contractions, 2) contractions with constant submaximal torque, and 3) contractions wit...
متن کاملA comparison of surface and fine wire EMG recordings of gluteus medius during selected maximum isometric voluntary contractions of the hip.
Electromyographic (EMG) studies into gluteus medius (GMed) typically involve surface EMG electrodes. Previous comparisons of surface and fine wire electrode recordings in other muscles during high load isometric tasks suggest that recordings between electrodes are comparable when the muscle is contracting at a high intensity, however, surface electrodes record additional activity when the muscl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
دوره 18 3 شماره
صفحات -
تاریخ انتشار 2008