Accuracy of high-resolution in vivo micro magnetic resonance imaging for measurements of microstructural and mechanical properties of human distal tibial bone.

نویسندگان

  • X Sherry Liu
  • X Henry Zhang
  • Chamith S Rajapakse
  • Michael J Wald
  • Jeremy Magland
  • Kiranjit K Sekhon
  • Mark F Adam
  • Paul Sajda
  • Felix W Wehrli
  • X Edward Guo
چکیده

Micro magnetic resonance imaging (µMRI) is an in vivo imaging method that permits 3D quantification of cortical and trabecular bone microstructure. µMR images can also be used for building microstructural finite element (µFE) models to assess bone stiffness, which highly correlates with bone's resistance to fractures. In order for µMRI-based microstructural and µFE analyses to become standard clinical tools for assessing bone quality, validation with a current gold standard, namely, high-resolution micro computed tomography (µCT), is required. Microstructural measurements of 25 human cadaveric distal tibias were performed for the registered µMR and µCT images, respectively. Next, whole bone stiffness, trabecular bone stiffness, and elastic moduli of cubic subvolumes of trabecular bone in both µMR and µCT images were determined by voxel-based µFE analysis. The bone volume fraction (BV/TV), trabecular number (Tb.N*), trabecular spacing (Tb.Sp*), cortical thickness (Ct.Th), and structure model index (SMI) based on µMRI showed strong correlations with µCT measurements (r(2) = 0.67 to 0.97), and bone surface-to-volume ratio (BS/BV), connectivity density (Conn.D), and degree of anisotropy (DA) had significant but moderate correlations (r(2) = 0.33 to 0.51). Each of these measurements also contributed to one or many of the µFE-predicted mechanical properties. However, model-independent trabecular thickness (Tb.Th*) based on µMRI had no correlation with the µCT measurement and did not contribute to any mechanical measurement. Furthermore, the whole bone and trabecular bone stiffness based on µMRI were highly correlated with those of µCT images (r(2) = 0.86 and 0.96), suggesting that µMRI-based µFE analyses can directly and accurately quantify whole bone mechanical competence. In contrast, the elastic moduli of the µMRI trabecular bone subvolume had significant but only moderate correlations with their gold standards (r(2) = 0.40 to 0.58). We conclude that most microstructural and mechanical properties of the distal tibia can be derived efficiently from µMR images and can provide additional information regarding bone quality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Resolution Peripheral Quantitative Computed Tomography Can Assess Microstructural and Mechanical Properties of Human Distal Tibial Bone

High-resolution peripheral quantitative computed tomography (HR-pQCT) is a newly developed in vivo clinical imaging modality. It can assess the 3D microstructure of cortical and trabecular bone at the distal radius and tibia and is suitable as an input for microstructural finite element (microFE) analysis to evaluate bone's mechanical competence. In order for microstructural and image-based mic...

متن کامل

Application of Magnetic Resonance Imaging (MRI) as a safe & Application of Magnetic Resonance Imaging (MRI) as a safe & non-destructive method for monitoring of fruit & vegetable in postharvest period

To investigate and control quality, one must be able to measure quality-related attributes. Quality of produce encompasses sensory attributes, nutritive values, chemical constituents, mechanical properties, functional properties and defects. MRI has great potential for evaluating the quality of fruits and vegetables. The equipment now available is not feasible for routine quality testing. The ...

متن کامل

Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging

Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...

متن کامل

Anthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population

Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...

متن کامل

Correlation of Anthropometric Measurements of Proximal Tibia in Iranian Knees with Size of Current Tibial Implants

of the Caucasian population. The purpose of this study was to investigate the morphometry of the proximal tibia in thestandard resected surface of total knee arthroplasty (TKA).Methods: In this descriptive study, the anthropometric data of the proximal tibia were measured in 132 knees (80 malesand 52 females) using magnetic resonance imaging in 2015. The collected data include...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research

دوره 25 9  شماره 

صفحات  -

تاریخ انتشار 2010